Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure
STANDARD published on 1.3.2018
Designation standards: ČSN EN 62232
Classification mark: 367927
Catalog number: 503899
Publication date standards: 1.3.2018
The number of pages: 250
Approximate weight : 781 g (1.72 lbs)
Country: Czech technical standard
Category: Technical standards ČSN
This document provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure.
This document:
a) considers intentionally radiating RBS which transmit on one or more antennas using one or more freque-ncies in the range 110 MHz to 100 GHz;
a) considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;
b) specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely:
1) product compliance - determination of compliance boundary information for an RBS product before it is placed on the market;
2) product installation compliance - determination of the total RF exposure levels in accessible areas from an RBS product and other relevant sources before the product is put into service;
3) in-situ RF exposure assessment - measurement of in-situ RF exposure levels in the vicinity of an RBS installation after the product has been taken into operation;
c) describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed RBS and laboratory-based eva-luations;
d) describes how surveyors, with a sufficient level of expertise, establish their specific evaluation procedures appropriate for their evaluation purpose;
e) provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value;
f) provides short descriptions of the informative example case studies given in the companion Technical Report IEC TR 62669 [1]