NORMSERVIS s.r.o.

IEC 61753-1-ed.2.0

Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance

STANDARD published on 15.8.2018

English and French -
electronic design (pdf) (532.70 USD)

English and French -
Print design (532.70 USD)

English and French -
CD-ROM (534.50 USD)

The information about the standard:

Designation standards: IEC 61753-1-ed.2.0
Publication date standards: 15.8.2018
The number of pages: 123
Approximate weight : 400 g (0.88 lbs)
Country: International technical standard
Category: Technical standards IEC

Annotation of standard text IEC 61753-1-ed.2.0 :

IEC 61753-1:2018 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general operating service environments and identifies those tests which are considered to be product specific. Test and severity details are given in Annex A. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) definitions updated with new products: wall outlets, wall or pole mounted boxes, splices, ODF modules, street cabinets, hardened connectors and field mountable connectors; b) categories U and O are replaced by categories OP and OP+. No mandatory sequence in category OP+. Category OP+ contains the tests from category OP with the addition of only 4 other tests; c) addition of Category I (Industrial); d) temperature ranges added (with the HD suffix to the categories C, OP, OP+ and I) in case passive optical components are placed in a housing together with active electronics (HD stands for “heat dissipation”); e) the height of category A changed from 3 m to ground level (0 m); f) the lower level height of category G environment changed from ground level (0 m) to –1 m below ground level. Upper level remains at 3 m above ground level; g) addition of performance tests, test severities and performance criteria for new products: Wall outlet, wall or pole mounted boxes, mechanical splices, fusion splice protectors, ODF modules, street cabinets, field mountable connectors and hardened optical connectors; h) test severity of "Mating durability" test for connectors in categories C, OP ,OP+ and I is reduced to 200 cycles for connectors with cylindrical ferrules and 50 cycles for connectors with rectangular ferrules; i) test severity of "Change of temperature" test for connectors and passive optical components in category I is reduced from 20 cycles to 12 cycles (harmonized with connectors and components from other categories); j) test severity of "Flexing of strain relief" test for connectors in categories C, OP and OP+ is reduced to 50 cycles; k) test severities of "Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures" test for all enclosures is reduced to 5 cycles; l) test severities of "Change of temperature" test for all protective housings in categories C, A, G and S is reduced from 20 cycles to 12 cycles (harmonized with connectors and components); m) test severities of "Resistance to solvents and contaminating fluids" test for closures in categories G and S changed – kerosene is removed, diesel oil exposure reduced to 1 h immersion and 24 h drying at room temperature; n) sealing performance criteria of sealed closures for categories G and A are reduced to 20 kPa overpressure. o) the change in attenuation criterion for connectors has changed from peak-to-peak into a +/- deviation from the original value of the transmitted power at the start of the test (harmonized with the change in attenuation criterion for components, splices and protective housings). Keywords: performance standards for all passive fibre optic products The contents of the corrigendum of May 2019 have been included in this copy. LIEC 61753-1:2018 fournit des recommandations pour la redaction de normes de qualite de fonctionnement applicables a tous les produits passifs fibroniques. Le present document definit les essais et les severites qui constituent les categories de qualite de fonctionnement ou les environnements de service ou de fonctionnement general et elle identifie les essais qui sont consideres comme specifiques a un produit. Les informations detaillees concernant les essais et les severites sont donnees a l’Annexe A. Cette deuxieme edition annule et remplace la premiere edition parue en 2007. Elle constitue une revision technique. Cette edition inclut les modifications techniques majeures suivantes par rapport a l’edition precedente: a) definitions mises a jour avec de nouveaux produits: prises murales, coffrets a montage mural ou sur poteau, epissures, modules ODF, armoires d’environnement urbain, connecteurs renforces et connexions montables sur le terrain; b) les categories U et O ont ete remplacees par les categories OP et OP+. Pas de sequence obligatoire dans la categorie OP+. La categorie OP+ contient les essais de la categorie OP avec l’ajout de seulement 4 autres essais; c) ajout de la categorie I (industriel); d) ajout des plages de temperature (avec le suffixe HD aux categories C, OP, OP+ et I) au cas ou des composants optiques passifs sont places dans un boitier avec des composants electroniques actifs (HD signifie Heat Dissipation, dissipation thermique); e) la hauteur de la categorie A a ete modifiee de 3 m au niveau du sol (0 m); f) la hauteur du niveau inferieur de l’environnement de categorie G a ete modifiee du niveau du sol (0 m) a –1 m en dessous du niveau du sol. Le niveau superieur reste a 3 m au-dessus du niveau du sol; g) ajout d’essais de performance, de severites d’essai et de criteres de qualite de fonctionnement pour de nouveaux produits: prises murales, coffrets a montage mural ou sur poteau, epissures mecaniques, protecteurs d’epissures par fusion, modules ODF, armoires d’environnement urbain, connexions montables sur le terrain et connecteurs optiques renforces; h) la severite de l’essai «Durabilite de l’accouplement» pour les connecteurs des categories C, OP, OP+ et I a ete ramenee a 200 cycles pour les connecteurs avec ferules cylindriques et a 50 cycles pour les connecteurs avec ferules rectangulaires; i) la severite de l’essai «Variations de temperature» pour les connecteurs et les composants optiques passifs de la categorie I a ete ramenee de 20 cycles a 12 cycles (harmonisee avec les connecteurs et les composants d’autres categories); j) la severite de l’essai «Fl