We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Management of Hazards Associated with Location of Process Plant Portable Buildings
Translate name
STANDARD published on 1.1.2024
Designation standards: API RP 753-ed.2
Publication date standards: 1.1.2024
SKU: NS-1163309
The number of pages: 66
Approximate weight : 198 g (0.44 lbs)
Country: American technical standard
Category: Technical standards API
API RP 753, 2nd Edition, January 2024 - Management of Hazards Associated with Location of Process Plant Portable Buildings
General
This recommended practice (RP) provides guidance for managing the risks from process-related explosion, fire, and toxic material release hazards to personnel located in on-site portable buildings.
The document is based on the API 752 guidance for siting evaluations and the referenced documents concerning its technical aspects. For guidance on the evaluation of each hazard type, the reader should reference API 752. This document provides clarifications and alterations where necessary to address portable buildings.
This RP covers:
Annex B provides examples on the coverage of permanent and portable buildings/tents.
This RP was developed for use at refineries, petrochemical and chemical operations, natural gas liquids extraction plants, natural gas liquefaction plants, and other onshore facilities, such as those covered by the Occupational Safety and Health Administration (OSHA) process safety management regulation, 29 CFR 1910.119 [1].
Non-process-related hazards exist that could present risks to building occupants including, but not limited to, fires originating from within the building, structural collapse due to extreme weather/seismic events, and objects falling on or striking the building. These non-process-related hazards are addressed by building design standards and applicable building codes/regulations, and are not within the scope of this RP.
Guiding Principles
API has established guiding principles for building/tent siting, which are used in API 752, API 753, and API 756. These guiding principles apply to all buildings and tents intended for occupancy:
These guiding principles reflect the concept of the hierarchy of controls. With respect to building hazards, mitigations arranged in a hierarchy, beginning with the most effective, involve:
Annex F in API 752, 4th Edition provides a summary of a few select events that clarify, illustrate, and emphasize the lessons learned that led to the development of these guiding principles.
Relationship with API 752 and API 756
New and existing permanent buildings are covered by API 752 [2].
New and existing portable buildings (other than light wood trailers) intended for perpetual use in a specific, fixed location are covered by API 752.
New and existing tents are covered by API 756 [3].
Table B.1 provides examples on the coverage of permanent and portable buildings/tents.
All references in this RP to API 752 and API 756 are to the 4th and 2nd Editions, respectively, which published concurrently with API 753.