We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Specification for Silver-Coated Soft or Annealed Copper Wire
STANDARD published on 15.11.2012
Designation standards: ASTM B298-12
Note: WITHDRAWN
Publication date standards: 15.11.2012
SKU: NS-6134
The number of pages: 8
Approximate weight : 24 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
copper wire silver-coated, silver-coated annealed copper wire, silver-coated copper electrical equipment wire, silver-coated soft copper wire, ICS Number Code 77.150.30 (Copper products)
1. Scope | ||||||||
1.1 This specification covers silver-coated, soft or annealed, round copper wire, intended for use in electrical equipment, as follows: 1.1.1 Class A—Wire whose silver coating is at least 1.25 % of the total weight of the coated wire. 1.1.2 Class B—Wire whose silver coating is at least 2.50 % of the total weight of the coated wire. 1.1.3 Class C—Wire whose silver coating is at least 4.00 % of the total weight of the coated wire. 1.1.4 Class D—Wire whose silver coating is at least 6.10 % of the total weight of the coated wire. 1.1.5 Class E—Wire whose silver coating is at least 10.00 % of the total weight of the coated wire. 1.2 Silver-coated wire having different minimum percentages of silver by weight may be obtained by mutual agreement between the manufacturer and the purchaser. For information purposes the thickness of coating in microinches provided by the percentages listed above is shown in Table 1 (Explanatory Note 1). Diameter, |
Area at 20°C |
Elongation |
Thickness of Coating, μin. (For Information Only) |
|||||
cmils |
in.2 |
Class A, 1.25 |
Class B, 2.50 |
Class C, 4.00 |
Class D, 6.10 |
Class E, 10.00 |
||
0.1285 |
16 510 |
0.01297 |
30 |
340 |
680 |
1 090 |
1 659 |
2 720 |
0.1144 |
13 090 |
0.01028 |
30 |
303 |
605 |
970 |
1 477 |
2 422 |
0.1019 |
10 380 |
0.008155 |
25 |
270 |
539 |
864 |
1 316 |
2 157 |
0.0907 |
8 230 |
0.00646 |
25 |
240 |
480 |
768 |
1 171 |
1 941 |
0.0808 |
6 530 |
0.00513 |
25 |
214 |
428 |
684 |
1 043 |
1 710 |
0.0720 |
5 180 |
0.00407 |
25 |
190 |
381 |
610 |
930 |
1 524 |
0.0641 |
4 110 |
0.00323 |
25 |
170 |
339 |
542 |
828 |
1 357 |
0.0571 |
3 260 |
0.00256 |
25 |
151 |
302 |
483 |
737 |
1 209 |
0.0508 |
2 580 |
0.00203 |
25 |
134 |
269 |
430 |
656 |
1 075 |
0.0453 |
2 050 |
0.00161 |
25 |
120 |
240 |
383 |
585 |
959 |
0.0403 |
1 620 |
0.00128 |
25 |
107 |
213 |
341 |
520 |
853 |
0.0359 |
1 290 |
0.00101 |
25 |
95 |
190 |
304 |
464 |
760 |
0.0320 |
1 020 |
0.000804 |
25 |
85 |
169 |
270 |
413 |
677 |
0.0285 |
812 |
0.000638 |
25 |
75 |
151 |
241 |
368 |
603 |
0.0253 |
640 |
0.000503 |
25 |
67 |
134 |
214 |
327 |
536 |
0.0226 |
511 |
0.000401 |
25 |
60 |
120 |
191 |
292 |
478 |
0.0201 |
404 |
0.00317 |
20 |
53 |
106 |
170 |
260 |
425 |
0.0179 |
320 |
0.000252 |
20 |
47 |
95 |
151 |
231 |
379 |
0.0159 |
253 |
0.000199 |
20 |
42 |
84 |
135 |
205 |
337 |
0.0142 |
202 |
0.000158 |
20 |
... |
75 |
120 |
183 |
301 |
0.0126 |
159 |
0.000125 |
20 |
... |
67 |
107 |
163 |
267 |
0.0113 |
128 |
0.000100 |
20 |
... |
60 |
96 |
146 |
239 |
0.0100 |
100 |
0.0000785 |
20 |
... |
53 |
85 |
129 |
212 |
0.0089 |
79.2 |
0.0000622 |
15 |
... |
47 |
75 |
115 |
188 |
0.0080 |
64.0 |
0.0000503 |
15 |
... |
42 |
68 |
103 |
169 |
0.0071 |
50.4 |
0.0000396 |
15 |
... |
... |
60 |
92 |
150 |
0.0063 |
39.7 |
0.0000312 |
15 |
... |
... |
53 |
81 |
133 |
0.0056 |
31.4 |
0.0000246 |
15 |
... |
... |
47 |
72 |
119 |
0.0050 |
25.0 |
0.0000196 |
15 |
... |
... |
42 |
65 |
106 |
0.0045 |
20.2 |
0.0000159 |
15 |
... |
... |
... |
58 |
95 |
0.0040 |
16.0 |
0.0000126 |
15 |
... |
... |
... |
52 |
85 |
0.0035 |
12.2 |
0.00000962 |
15 |
... |
... |
... |
45 |
74 |
0.0031 |
9.61 |
0.00000755 |
15 |
... |
... |
... |
40 |
66 |
0.0028 |
7.84 |
0.00000616 |
10 |
... |
... |
... |
... |
59 |
0.0025 |
6.25 |
0.00000491 |
10 |
... |
... |
... |
... |
53 |
0.0022 |
4.84 |
0.00000380 |
10 |
... |
... |
... |
... |
47 |
|
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3.1 Exceptions—The SI values for density, resistivity, and volume are to be regarded as standard.
1.4 The following
precautionary caveat pertains only to the test method section of
this specification: This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Practices for Apparatus,
Reagents, and Safety Considerations for Chemical Analysis of
Metals, Ores, and Related Materials Standard Specification for Standard
Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid
Round Wires Used as Electrical Conductors Standard Specification for Copper Rod for
Electrical Purposes Standard Test Method for Resistivity of
Electrical Conductor Materials