We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers (Withdrawn 2019)
Automatically translated name:
Standard Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers
STANDARD published on 1.6.2010
Designation standards: ASTM C1041-10
Note: WITHDRAWN
Publication date standards: 1.6.2010
SKU: NS-9169
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
heat flux, heat flux transducer, industrial application, in situ measurement, Protective linings, Sensors, Tanks, Thermal transmission properties, Field testing--thermal insulation, Heat flux, Industrial buildings/developments, Boilers, Ovens, Pipe thermal insulation, ICS Number Code 27.220 (Heat recovery. Thermal insulation)
Significance and Use | ||||||||||
The major contribution of this practice is that it enables a measurement of the real-time energy loss or gain through a chosen surface of an existing process insulation with minimal disturbance to the heat flux through the insulating body. The primary use of this practice will be for the in-situ estimation of thermal transport properties of industrial insulation such as used on pipes, tanks, ovens, and boilers, operating under normal process conditions. Errors attributable to heat flow measurements over a small area or short term testing can be misleading and this practice is intended to minimize such errors. Insulation processes with large temperature differences across the insulation are best suited to HFT measurements because modest changes in ambient conditions have but minimal effects on HFT output. While it would be ideal for the HFT and attachment system to have zero thermal resistance, this factor is insignificant to the measured result if kept to 5 % or less of the resistance of the insulating section being tested. |
||||||||||
1. Scope | ||||||||||
1.1 This practice covers the in-situ measurement of heat flux through industrial thermal insulation using a heat flux transducer (HFT). 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This practice estimates the thermal transport properties of thermal insulation materials in-situ in field applications under pseudo steady-state conditions. It is not intended that this practice should be used as a substitute for more precise laboratory procedures such as Test Methods C177, C335, or C518. 1.4 This practice is limited by the relatively small area that can be covered by an HFT and by the transient effects of environmental conditions. 1.5 Temperature limitations shall be as specified by the manufacturer of the HFT. 1.6 While accurate values of heat flux are highly dependent upon proper calibrations under the conditions of use, it is acceptable to use the calibrations provided by the manufacturer of the HFT for comparative work between similar materials, aging, or other conditions of use. Note 1—Further information may be found in the literature (1-6). 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.