We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
STANDARD published on 1.6.2009
Designation standards: ASTM C1103-03(2009)
Note: WITHDRAWN
Publication date standards: 1.6.2009
SKU: NS-9507
The number of pages: 2
Approximate weight : 6 g (0.01 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
Acceptance criteria/testing, Concrete pipe, Field testing--concrete/aggregates, Ground-water pressure, Joints (concrete applications), Pressure testing--concrete pipe, Sewer pipe (concrete), ICS Number Code 23.040.50 (Pipes and fittings of other materials)
Significance and Use | ||||
This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing. |
||||
1. Scope | ||||
1.1 This practice covers procedures for testing the joints of installed precast concrete pipe sewer lines, when using either air or water under low pressure to demonstrate the integrity of the joint and the construction procedures. This practice is used for testing 27-in. and larger diameter precast concrete sewer lines utilizing rubber gasket sealed joints. Note 1—The user of this test method is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery. 1.2 This practice is the inch-pound companion to Practice C 1103M; therefore, no SI equivalents are presented in the practice. Note 2—The owner shall specify the following: who will conduct, observe, and furnish labor, material, and measuring devices and pay for the tests; who is responsible for determining local ground conditions; and whether an air or water test is to be used. Note 3—The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe 24-in. diameter and smaller shall be accepted by infiltration or exfiltration testing utilizing Practice C 969 or by low pressure air testing utilizing Practice C 924. Pipe greater than 24-in. diameter shall be accepted by infiltration or exfiltration testing utilizing C 969. Note 4—The user of this practice is advised that no correlation has been found between air loss and water leakage. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautions are given in Section 6. |
||||
2. Referenced Documents | ||||
|
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.