We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Tensile Strength of Monolithic Advanced Ceramics at Elevated Temperatures
STANDARD published on 1.8.2013
Designation standards: ASTM C1366-04(2013)
Note: WITHDRAWN
Publication date standards: 1.8.2013
SKU: NS-10876
The number of pages: 27
Approximate weight : 81 g (0.18 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
advanced ceramic, elevated temperatures, percent bending, tensile strength, tensile testing, ICS Number Code 81.060.30 (Advanced ceramics)
Significance and Use | ||||||||||||||||||||||||||||
4.1 This test method may be used for material development, material comparison, quality assurance, characterization, reliability assessment, and design data generation. 4.2 High strength, monolithic advanced ceramic materials are generally characterized by small grain sizes (< 50 μm) and bulk densities near the theoretical density. These materials are candidates for load-bearing structural applications requiring high degrees of wear and corrosion resistance and elevated-temperature strength. Although flexural test methods are commonly used to evaluate strength of advanced ceramics, the non uniform stress distribution of the flexure specimen limits the volume of material subjected to the maximum applied stress at fracture. Uniaxially-loaded tensile strength tests provide information on strength-limiting flaws from a greater volume of uniformly stressed material. 4.3 Because of the probabilistic strength distributions of brittle materials such as advanced ceramics, a sufficient number of test specimens at each testing condition is required for statistical analysis and eventual design with guidelines for sufficient numbers provided in this test method. Size-scaling effects as discussed in practice C1239 will affect the strength values. Therefore, strengths obtained using different recommended tensile test specimen geometries with different volumes or surface areas of material in the gage sections will be different due to these size differences. Resulting strength values can, in principle, be scaled to an effective volume or effective surface area of unity as discussed in Practice C1239. 4.4 Tensile tests provide information on the strength and deformation of materials under uniaxial stresses. Uniform stress states are required to effectively evaluate any non-linear stress-strain behavior which may develop as the result of testing mode, testing rate, processing or alloying effects, environmental influences, or elevated temperatures. These effects may be consequences of stress corrosion or sub critical (slow) crack growth which can be minimized by testing at appropriately rapid rates as outlined in this test method. 4.5 The results of tensile tests of specimens fabricated to standardized dimensions from a particular material or selected portions of a part, or both, may not totally represent the strength and deformation properties of the entire, full-size end product or its in-service behavior in different environments. 4.6 For quality control purposes, results derived from standardized tensile test specimens can be considered to be indicative of the response of the material from which they were taken for particular primary processing conditions and post-processing heat treatments. 4.7 The tensile strength of a ceramic material is dependent on both its inherent resistance to fracture and the presence of flaws. Analysis of fracture surfaces and fractography as described in Practice C1322 and MIL-HDBK-790, though beyond the scope of this test method, are recommended for all purposes, especially for design data. |
||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||
1.1 This test method covers the determination of tensile strength under uniaxial loading of monolithic advanced ceramics at elevated temperatures. This test method addresses, but is not restricted to, various suggested test specimen geometries as listed in the appendix. In addition, test specimen fabrication methods, testing modes (force, displacement, or strain control), testing rates (force rate, stress rate, displacement rate, or strain rate), allowable bending, and data collection and reporting procedures are addressed. Tensile strength as used in this test method refers to the tensile strength obtained under uniaxial loading. 1.2 This test method applies primarily to advanced ceramics which macroscopically exhibit isotropic, homogeneous, continuous behavior. While this test method applies primarily to monolithic advanced ceramics, certain whisker, or particle-reinforced composite ceramics as well as certain discontinuous fiber-reinforced composite ceramics may also meet these macroscopic behavior assumptions. Generally, continuous fiber ceramic composites (CFCCs) do not macroscopically exhibit isotropic, homogeneous, continuous behavior and application of this test method to these materials is not recommended. 1.3 The values stated in SI units are to be regarded as the standard and are in accordance with Practice E380. 1.4 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Test Method for Calibration of
Thermocouples By Comparison Techniques Standard Test Method for Measuring
Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb
Temperatures) Standard Practice for Use of the
Internation System of Units (SI) (the Modernized Metric System)
(Withdrawn 1997) IEEE/ASTM SI 10 Standard for Use of the International
System of Units (SI) (The Modern Metric System) Standard Practice for Verification of
Testing Frame and Specimen Alignment Under Tensile and Compressive
Axial Force Application Standard Terminology of Advanced
Ceramics Standard Test Method for Flexural
Strength of Advanced Ceramics at Ambient Temperature Standard Practice for Reporting Uniaxial
Strength Data and Estimating Weibull Distribution Parameters for
Advanced Ceramics Standard Practice for Fractography and
Characterization of Fracture Origins in Advanced Ceramics Standard Test Method for Tensile Strength
and Young's Modulus for High-Modulus Single-Filament Materials
(Withdrawn 1998) Standard Practices for Force Calibration
and Verification of Testing Machines Standard Terminology Relating to Methods
of Mechanical Testing (Includes all amendments and changes
3/29/2023). Standard Test Methods for Elevated
Temperature Tension Tests of Metallic Materials Standard Practice for Verification and
Classification of Extensometer Systems |
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-02-20 (Number of items: 2 227 658)
© Copyright 2025 NORMSERVIS s.r.o.