ceiling, coreboard, drywall, exterior gypsum soffit board, foil-backed, gypsum, gypsum backing board, gypsum base, gypsum board, gypsum ceiling board, gypsum coreboard, gypsum lath, gypsum sheathing, gypsum sheathing board, gypsum wallboard, laminated gypsum board, partitions, plaster, predecorated gypsum board, shaftliner, sheathing, type X, veneer base, veneer plaster, wall, wallboard, water-resistant gypsum board,
1. Scope | ||||||||||||||||||||||||||||
1.1 This specification covers the gypsum boards described in 1.1.1 – 1.1.9. Note 1: Specifications C840, C841, C844 and C1280 contain application procedures for
gypsum board.
1.1.1 Gypsum wallboard, designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration. 1.1.2 Predecorated gypsum board, designed for use as the finished surfacing for walls, ceilings, or partitions. 1.1.3 Gypsum backing board, coreboard, and shaftliner board, designed for use as a base in multilayer systems or as a gypsum stud or core in semisolid or solid gypsum board partitions, or in shaft wall assemblies. Note 2: The terms backing board, coreboard, and shaftliner
board refer to different end uses. The term gypsum backing board,
as used in this specification, shall include gypsum coreboard and
gypsum shaftliner board unless otherwise stated.
1.1.4 Water-resistant gypsum backing board, designed primarily to be used as a base for the application of ceramic or plastic tile on walls or ceilings. This product is also suitable for decoration. 1.1.5 Exterior gypsum soffit board, designed for use on exterior soffits and carport ceilings that are completely protected from contact with liquid water. 1.1.6 Gypsum sheathing board, designed for use as sheathing on buildings. 1.1.7 Gypsum base for veneer plaster, designed for use as a base for the application of gypsum veneer plaster. 1.1.8 Gypsum lath, designed for use as a base for the application of gypsum plaster. 1.1.9 Gypsum ceiling board, designed for use on interior ceilings with framing spaced not more than 24 in. [610 mm] on center and that affords a surface suitable to receive water-based texture and other decoration. This product is also suitable for use on interior walls. 1.2 Specifications applicable to all gypsum boards are located in Section 1 – 4 and 13 – 15. Specifications applicable to specific gypsum boards are located in the following sections:
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.