We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Flexural Toughness of Fiber Reinforced Concrete (Using Centrally Loaded Round Panel) (Includes all amendments And changes 11/13/2019).
Automatically translated name:
Standard Test Method for Flexural Toughness of Fiber Reinforced Concrete (Using Centrally Loaded Round Panel)
STANDARD published on 1.12.2012
Designation standards: ASTM C1550-12a
Note: WITHDRAWN
Publication date standards: 1.12.2012
SKU: NS-11803
The number of pages: 13
Approximate weight : 39 g (0.09 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
energy absorption, fiber-reinforced concrete, flexure, post-crack behavior, toughness, ICS Number Code 91.100.40 (Products in fibre-reinforced cement)
Significance and Use | ||||||
5.1 The post-crack behavior of plate-like, fiber-reinforced concrete structural members is well represented by a centrally loaded round panel test specimen that is simply supported on three pivots symmetrically arranged around its circumference. Such a test panel experiences bi-axial bending in response to a central point load and exhibits a mode of failure related to the in situ behavior of structures. The post-crack performance of round panels subject to a central point load can be represented by the energy absorbed by the panel up to a specified central deflection. In this test method, the energy absorbed up to a specified central deflection is taken to represent the ability of a fiber-reinforced concrete to redistribute stress following cracking. 5.2 The motivation for use of a
round panel with three supports is based on the within-batch
repeatability found in laboratory3 and field
experience.5.3 The nominal dimensions of the
panel are 75 mm in thickness and 800 mm in diameter. Thickness has
been shown to strongly influence panel performance in this test,
while variations in diameter have been shown to exert a minor
influence on performance.5 Correction
factors are provided to account for actual measured dimensions.
1.1 This test method covers the
determination of flexural toughness of fiber-reinforced concrete
expressed as energy absorption in the post-crack range using a
round panel supported on three symmetrically arranged pivots and
subjected to a central point load. The performance of specimens
tested by this method is quantified in terms of the energy absorbed
between the onset of loading and selected values of central
deflection.
1.2 This test method provides for the scaling of results whenever specimens do not comply with the target thickness and diameter, as long as dimensions do not fall outside of given limits. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historical
1.11.2009
Historical
1.11.2011
Historical
1.11.2009
Historical
1.11.2012
Historical
15.12.2012
Historical
1.11.2012
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.