We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Compressive Strength of Hydraulic-Cement Mortars (Using Portions of Prisms Broken in Flexure)
STANDARD published on 1.12.2008
Designation standards: ASTM C349-08
Note: WITHDRAWN
Publication date standards: 1.12.2008
SKU: NS-13056
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
compressive strength, hydraulic-cement mortar, hydraulic-cement strength, mortar strength, strength, Cement mortars, Compression testing--cement/concrete, Hydraulic cement concrete, Hydraulic cement mortar, Hydraulic-cement strength, Mortar strength, Strength--cement/concrete mixtures/applications, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
Significance and Use | ||||||||
This method provides a means of obtaining compressive strength values from the same specimens previously used for flexural strength determinations by Test Method C 348. The compressive strength values are for reference purposes, and not as substitutes for values obtained by Test Method C 109/C 109M for cement acceptance. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination of the compressive strength of hydraulic-cement mortars, using for the test specimens portions of prisms made and broken in flexure in accordance with Test Method C 348. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and rounding given in Standard IEEE/ASTM SI 10, of measurements made in other units. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. ) |
||||||||
2. Referenced Documents | ||||||||
|