Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 60 ?C Operation
Translate name
STANDARD published on 1.1.2021
Designation standards: ASTM D2219-21
Publication date standards: 1.1.2021
SKU: NS-1018225
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
This specification covers thermoplastic insulating materials made of poly(vinyl chloride) or the copolymer of vinyl chloride and vinyl acetate recommended for use in wires and cables operating in wet or dry locations at specified conductor temperatures and maximum voltage ratings for power and control circuits. Since the insulation material cannot be tested unless it has been formed around a conductor or cable, tests shall then be done on insulated wire or cable solely to determine the relevant property of the insulation material and not to test the conductor or completed cable. Materials shall conform to the following physical requirements: unaged tensile strength and elongation at rupture; tensile strength and elongation after air oven aging; heat shock; heat distortion; behavior during vertical flame test; oil resistance; tensile strength and elongation after oil immersion; behavior during cold bend test, and size and thickness. Insulations shall also perform satisfactorily during tests for AC and DC voltage, insulation resistance, accelerated water absorption, and dielectric strength retention.
Keywords:
60 ?C poly (vinyl chloride) insulation, ac voltage test, accelerated water absorption, dc voltage test, insulation resistance, poly (vinyl chloride) insulation, thickness ,, ICS Number Code 29.035.20 (Plastic and rubber insulating materials)
1. Scope | ||||
1.1?This specification covers a thermoplastic insulation of poly(vinyl chloride) or the copolymer of vinyl chloride and vinyl acetate. 1.2?This insulation is recommended for use at conductor temperatures not in excess of 60 ?C in wet or dry locations at a maximum voltage rating of 600 V for power and control circuits. 1.3?In many instances, the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable. 1.4?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4.1?In some cases (including the title), temperatures are described in degrees Celsius only. 1.5?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||
2. Referenced Documents | ||||
|