Standard Test Method for Particle Size Distribution of Granular Activated Carbon
STANDARD published on 1.4.2010
Designation standards: ASTM D2862-10
Note: WITHDRAWN
Publication date standards: 1.4.2010
SKU: NS-21743
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
granular activated carbon, particle size distribution, Activated carbon--granular, Particle size distribution, ICS Number Code 19.120 (Particle size analysis. Sieving)
Significance and Use | ||||||||||||
It is necessary to know the distribution of particle sizes of granular activated carbon in order to provide proper contact of gases or liquid in a packed bed of the material. Changes in particle size distribution can affect the pressure drop across the bed and the rate of adsorption in a bed of a given size. Mean particle diameter is a property of activated carbons that influences pressure drop. Effective size and uniformity coefficient are two properties of activated carbons often of interest in municipal water treatment applications where control of particle size is of interest. |
||||||||||||
1. Scope | ||||||||||||
1.1 This test method covers the determination of the particle size distribution of granular activated carbon. For the purposes of this test, granular activated carbon is defined as a minimum of 90 % of the sample weight being retained on a 180-μm Standard sieve. A U.S. mesh 80 sieve is equivalent to a 180–μm Standard sieve. Note 1—For extruded carbons, as the length/diameter ratio of the particles increases, the validity of the test results might be affected. 1.2 The data obtained may also be used to calculate mean particle diameter (MPD), effective size, and uniformity coefficient. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3.1 Exception—All mass measurements are in SI units only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Historical
1.4.2011
Historical
1.11.2013
Historical
1.10.2013
Historical
1.4.2011
Historical
15.11.2011
Historical
1.10.2013
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-11-26 (Number of items: 2 206 223)
© Copyright 2024 NORMSERVIS s.r.o.