Standard Test Method for Evaluation of Resistance to Electrical Breakdown by Treeing in Solid Dielectric Materials Using Diverging Fields
STANDARD published on 1.10.2010
Designation standards: ASTM D3756-97(2010)
Note: WITHDRAWN
Publication date standards: 1.10.2010
SKU: NS-24739
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
needles, partial discharge, resistance to electrical breakdown, treeing, voltage life, Contamination--insulation materials/applications, Dielectric breakdown voltage, Electrical insulating solids, Electrical properties, Electrical resistance/resistivity--insulating materials, Electrodes, Needle test, Treeing, ICS Number Code 29.035.01 (Insulating materials in general)
Significance and Use | ||||||||||
This is a laboratory test designed to simulate the effects of (1) the presence of rough interfaces between conductor or semiconductive screen and primary insulation in an insulation system, (2) the presence of foreign particles (contaminants) in an insulation system, and (3) the presence of small voids or cavities within the insulation. This test method provides comparative data. The degree of correlation with actual performance in service has not been established. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the evaluation and comparison of the resistance of solid organic dielectric materials to the initiation or growth, or both, of tubular tree-like channels resulting from partial discharge (corona) and molecular decomposition that occur in the region of very high, diverging electric fields. , 1.2 This test method is primarily for use at a power frequency of 50 or 60 Hz. 1.3 The test may be carried out at room temperature or temperatures above or below room temperature. The temperature should not exceed the softening or melting point of the sample material. 1.4 This test method can be used for any solid material into which needles can be cast, molded, or inserted with heat after molding. The resistance to tree initiation is measured by the double-needle characteristic voltage, which is only applicable to non-opaque materials so that tree can be observed optically. The resistance to tree initiation and growth is reported by the double-needle voltage life, which is applicable to both opaque and non-opaque materials. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.11.2013
Historical
1.4.2013
Historical
1.10.2010
Historical
1.5.2013
Historical
1.4.2014
Historical
1.10.2006
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.