Standard Specification for Fiber-Reinforced Plastic Fans and Blowers
STANDARD published on 1.11.2007
Designation standards: ASTM D4167-97(2007)
Note: WITHDRAWN
Publication date standards: 1.11.2007
SKU: NS-26279
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
axial blowers, centrifugal blowers, fan balancing, fan housing, fan wheel, fiber-reinforced plastic fans (frp), safe operating speed, Blowers, Fans, Fiber-reinforced-plastic (FRP), Plastics specifications, Reinforced thermosetting plastics (RTP) specifications, ICS Number Code 23.120 (Ventilators. Fans. Air-conditioners)
1. Scope | ||||||||||||||||||||
1.1 This specification covers centrifugal and axial fans and blowers with airstream components fabricated of fiber-reinforced thermoset plastics (FRP) for corrosion resistance. Internal structures may include encapsulated metal fastening devices, hubs, and shafts. 1.2 Reinforcing materials other than fibrous glass may be used in the fabrication, provided the fans and blowers produced meet all the requirements of this specification. 1.3 The term “fans” as used in this specification includes fans and blowers, both centrifugal and axial. 1.4 The purpose of this specification is to provide users, system designers, specifiers, and manufacturers of FRP fans with minimum standards for fan construction and a common basis for determining safe operating speeds. 1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only. Note 1—There is no similar or equivalent ISO standard. Note 2—Appendix X2 contains a list of documents that may be of interest to designers of fan systems. 1.6 This standard does not puport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and helath practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-01-06 (Number of items: 2 218 326)
© Copyright 2025 NORMSERVIS s.r.o.