We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Anions in Water by Suppressed Ion Chromatography
STANDARD published on 1.3.2011
Designation standards: ASTM D4327-11
Note: WITHDRAWN
Publication date standards: 1.3.2011
SKU: NS-26854
The number of pages: 12
Approximate weight : 36 g (0.08 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
anions, drinking water, ion chromatography, reagent water, wastewater, Anions content, Bromide (ion) analysis, Chloride analysis--water applications, Fluoride (ion) analysis, Halide (ion) content, Inorganic compounds--water, Ion chromatography (IC), Nitrate (ion) analysis, Organic compounds--water, Phosphate (ion) analysis, ICS Number Code 71.040.40 (Chemical analysis)
Significance and Use | ||||||||||||||
Ion chromatography provides for both qualitative and quantitative determination of seven common anions, F−, Cl−, NO2−, HPO4−2, Br−, NO3−, and SO4−2, in the milligram per liter range from a single analytical operation requiring only a few milliliters of sample and taking approximately 10 to 15 min for completion. Additional anions, such as carboxylic acids, can also be quantified. Note 2—This test method may be used to determine fluoride if its peak is in the water dip by adding one mL of eluent (at 100× the concentration in 8.3) to all 100-mL volumes of samples and standards to negate the effect of the water dip. (See 6.3, and also see 6.4.) The quantitation of unretained peaks should be avoided. Anions such as low molecular weight organic acids (formate, acetate, propionate, etc.) that are conductive coelute with fluoride and would bias fluoride quantitation in some drinking waters and most wastewaters. The water dip can be further minimized if measures are taken to remove carbonic acid which remain in the eluent after suppression using carbonate based eluents. There is no water dip if hydroxide eluents are used. Anion combinations such as Cl−/Br− and NO2−/NO3−, which may be difficult to distinguish by other analytical methods, are readily separated by ion chromatography. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method covers the sequential determination of fluoride, chloride, nitrite, ortho-phosphate, bromide, nitrate, and sulfate ions in water by suppressed ion chromatography. Note 1—Order of elution is dependent upon the column used; see Fig. 1. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historical
15.6.2011
Historical
1.9.2012
Historical
15.11.2008
Historical
1.10.2008
Historical
1.9.2011
Historical
1.4.2011
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-29 (Number of items: 2 209 787)
© Copyright 2024 NORMSERVIS s.r.o.