We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Analysis of Benzene by Gas Chromatography (Withdrawn 2018)
Automatically translated name:
Standard Test Method for Analysis of Benzene by Gas Chromatography
STANDARD published on 15.3.2010
Designation standards: ASTM D4492-10
Note: WITHDRAWN
Publication date standards: 15.3.2010
SKU: NS-27461
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
benzene, gas chromatography, purity, Impurities--organic compounds, Nonaromatic impurities, Purity analysis--paints/related coatings/materials, Trace elements--paints/related coatings/materials, Benzene--paints/related coatings/materials, Gas chromatography (GC)--paints/related coatings/materials, ICS Number Code 71.080.15 (Aromatic hydrocarbons)
Significance and Use | ||||||||||||||||||
This test method is suitable for determining the concentrations of known impurities in finished benzene and for use as an integral quality control tool where benzene is either produced or used in a manufacturing procedure. It is generally applied to impurities such as nonaromatics containing nine carbons or less, toluene, C8 aromatics, and 1,4-dioxane. Absolute purity cannot be determined if unknown impurities are present. Test Method D852 is generally used as a criteria for determining the absolute purity. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This test method covers the determination of normally occurring trace impurities in, and the purity of, finished benzene by gas chromatography. 1.2 This test method is applicable for benzene purities of 99.80 weight % or higher. 1.3 The lower limit for detection for non-aromatic impurities is 50 mg/kg. The lower limit of detection for individual aromatic hydrocarbon impurities 10 mg/kg. The lower limit of detection for 1,4-dioxane is 5 mg/kg. 1.4 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding off method of Practice E29. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historical
1.3.2012
Historical
15.1.2009
Historical
1.1.2011
Historical
1.6.2010
Historical
1.6.2012
Historical
1.6.2011
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.