We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions
STANDARD published on 1.8.2011
Designation standards: ASTM D5032-11
Note: WITHDRAWN
Publication date standards: 1.8.2011
SKU: NS-29580
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Ventilation and air-conditioning systemsGeology. Meteorology. Hydrology
Keywords:
aqueous glycerin solutions, conditioning, constant relative humidity, glycerin, relative humidity: Aqueous solutions, Atmospheres--conditioning/testing, Conditioning--electrical insulating materials, Constant relafive humidity, Contamination prevention, Controlled testing conditions/environments, Dielectric breakdown voltage, Dielectric properties/testing, Glycerin, Permittivity (dielectric constant), Relative humidity (RH), Temperature tests--room
Significance and Use | ||||||||||
Controlled relative humidity environments are important for conditioning materials for shelf-life studies or for investigating the change in physical or dielectric properties after exposure. The use of aqueous-glycerin solutions reduces the possibility of contamination of the materials or corrosion of electrode systems which would be more likely to result from saturated salt or acid water solutions. Applicable material specifications should state the exposure conditions, including time, temperature and relative humidity that a material should be subjected to before subsequent testing. Typical conditions are given in Practice D618 or D6054. |
||||||||||
1. Scope | ||||||||||
1.1 This practice describes a method for obtaining constant relative humidity ranging from 30 to 98 % at temperatures ranging from 0 to 70°C in relatively small containers by means of an aqueous glycerin solution. 1.2 This practice is applicable for closed systems such as environmental conditioning containers. 1.3 This practice is not recommended for the generation of continuous (flowing) streams of constant humidity unless precautionary criteria are followed to ensure source stability. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.8.2013
Historical
1.5.2014
Historical
15.1.2010
Historical
1.10.2013
Historical
1.8.2012
Historical
1.1.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.