Standard Test Methods for Estimating Contribution of Environmental Tobacco Smoke to Respirable Suspended Particles Based on UVPM and FPM
STANDARD published on 10.5.2002
Designation standards: ASTM D5955-02
Note: WITHDRAWN
Publication date standards: 10.5.2002
SKU: NS-33183
The number of pages: 9
Approximate weight : 27 g (0.06 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
environmental tobacco smoke (ETS), fluorescent particulate matter (FPM), indoor air quality, respirable suspended particles (RSP), ultraviolet particulate matter (UVPM), ICS Number Code 13.040.01 (Air quality in general)
1. Scope | ||||||||||
1.1 These test methods pertain to the sampling/analysis of respirable suspended particles (RSP) and the estimation of the RSP fraction attributable to environmental tobacco smoke (ETS). These test methods are based on collection of total RSP on a membrane filter, extracting the collected material in methanol, and measuring total ultraviolet absorbance or fluorescence, or both, of this extract. The corresponding methods of estimation are termed ultraviolet particulate matter (UVPM) and fluorescent particulate matter (FPM), respectively. 1.2 These test methods are compatible with, but do not require the determination of solanesol, which is also used to estimate the contribution of ETS to RSP (see Test Method D 6271). 1.3 The sampling components consist of a preweighed, 1.0-m pore size polytetrafluoroethylene (PTFE) membrane filter in a filter cassette connected on the inlet end to a particle size separating device and, on the outlet end, to a sampling pump. These test methods are applicable to personal and area sampling. 1.4 These test methods are limited in sample duration only by the capacity of the membrane filter (about 2000 g). These test methods have been evaluated up to a 24-h sample duration with a minimum sample duration of at least 1 h. 1.5 Limits of detection (LOD) and quantitation (LOQ) for the UVPM test method at a sampling rate of 2 L/min are, respectively, 2.5 g/m3 and 8.3 g/m3 for a 1-h sample duration and 0.3 g/m3 and 1.0 g/m3 for an 8-h sample duration. The LOD and LOQ for the FPM test method at a sampling rate of 2 L/min are, respectively, 1.4 μg/m3 and 4.7 μg/m 3 for a 1-h sample duration and 0.2 μg/m3 and 0.6 μg/m 3 for an 8-h sample duration. 1.6 The values stated in SI units are to be regarded as standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary information is given in 13.6. |
||||||||||
2. Referenced Documents | ||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-21 (Number of items: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.