We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Separation and Identification of Poly(Vinyl Chloride) (PVC) Contamination in Poly(Ethylene Terephthalate) (PET) Flake
STANDARD published on 1.2.2009
Designation standards: ASTM D5991-09
Note: WITHDRAWN
Publication date standards: 1.2.2009
SKU: NS-33345
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
contamination, poly(ethylene terephthalate) (PET), poly(vinyl chloride) (PVC), recycled plastics, Contamination--plastics, Identification, PET (poly(ethylene terephthalate)), Poly(vinyl chloride)(PVC), Recycled plastics, ICS Number Code 83.080.10 (Thermosetting materials)
Significance and Use | ||||||
Presence of even low concentrations of PVC in recycled PET flakes may result in equipment corrosion problems during processing. The level of PVC contamination may also dictate the market for use of the recycled polymer in secondary products. Procedures presented in this practice are used to identify and, if desired, estimate the concentration of PVC contamination in recycled PET flakes. |
||||||
1. Scope | ||||||
1.1 This practice covers four procedures for separation and qualitative identification of poly(vinyl chloride) (PVC) contamination in poly(ethylene terephthalate) (PET) flakes. Note 1—Although not presented as a quantitative method, procedures presented in this practice may be used to provide quantitative results at the discretion of the user. The user assumes the responsibility to verify the reproducibility of quantitative results. Data from an independent source suggest a PVC detection level of 200 ppm (w/w) based on an original sample weight of 454 g. 1.2 Procedure A is based on different fluorescence of PVC and PET when these polymers are exposed to ultraviolet (UV) light. 1.3 Procedure B is an oven test based upon the charring of PVC when it is heated in air at 235°C. 1.4 Procedures C and D are dye tests based on differential staining of PVC and PET. Note 2—Other polymers (for example, PETG) also absorb the stain or brightener. Such interferences will result in false positive identification of PVC as the contaminant. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards see Section 8. Note 3—There is no known ISO equivalent to this practice. |
||||||
2. Referenced Documents | ||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-04-17 (Number of items: 2 197 070)
© Copyright 2025 NORMSERVIS s.r.o.