We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Peel Adhesion of Pressure-Sensitive Label Stocks at a 90° Angle
STANDARD published on 1.4.2011
Designation standards: ASTM D6252/D6252M-98(2011)
Note: WITHDRAWN
Publication date standards: 1.4.2011
SKU: NS-34404
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
label stock, peel adhesion at 90° angle, pressure-sensitive label stock, Labels/labeling, Peel adhesion, Pressure-sensitive materials/applications, Quality assurance (QA), ICS Number Code 83.180 (Adhesives)
Significance and Use | ||||||||||
This test method is a tool for quality assurance use. Given a pressure-sensitive label stock and a requirement in terms of the minimum or maximum peel adhesion value expected for this label stock, the data from the test can be used in conjunction with acceptance criteria. This test method can show the relative bond strength of a given label stock to one or more surfaces of varied material and texture as compared to the standard stainless steel panel. Substitution of panels representative of the proposed substrates for the standard stainless steel panel would be acceptable for this procedure. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the measurement of the peel adhesion of pressure-sensitive label stocks. This test method gives a measure of the adherence to a standard steel substrate or to other surfaces of interest for a pressure-sensitive label stock. 1.2 This test method provides a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive label stock. The assessment may be within a sheet or roll, between sheets or rolls, or between production lots. 1.3 Variations in the label stock facestock and adhesive can affect the response; therefore, this test method cannot be used to pinpoint the specific cause(s) of nonuniformity. 1.4 This test method may not be appropriate to test label stocks having either stiff backings or backings showing a high stretch at low forces. These characteristics could result in a high variability of the test response, which is not a true indication of the real nature of the adhesive bond. 1.5 The values stated in either SI or inch-pound units are to be regarded separately as the standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently, without combining values in any way. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.10.2013
Historical
1.1.2011
Historical
1.10.2012
Historical
1.5.2012
Historical
1.7.2013
Historical
1.10.2013
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-29 (Number of items: 2 209 787)
© Copyright 2024 NORMSERVIS s.r.o.