We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Guide for Laboratory Subsampling of Media Related to Waste Management Activities (Withdrawn 2018) (Includes all amendments And changes 2/5/2019).
Automatically translated name:
Standard Guide for Laboratory Subsampling of Media Related to Waste Management Activities
STANDARD published on 1.11.2012
Designation standards: ASTM D6323-12e1
Note: WITHDRAWN
Publication date standards: 1.11.2012
SKU: NS-34668
The number of pages: 12
Approximate weight : 36 g (0.08 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
sample preparation, subsampling, waste, ICS Number Code 13.030.99 (Other standards related to wastes)
Significance and Use | ||||||||||||||||||||||
4.1 This guide discusses options for taking a subsample from a sample submitted to a laboratory. If followed, it will minimize the bias and variance of the characteristic of interest of the laboratory sample prior to analysis. 4.2 The guide will describe appropriate instructions to be submitted to the laboratory with the field sample. 4.3 This guide is intended for use in the laboratory to take a representative subsample or specimen of the whole field sample for direct analysis or sample preparation for analysis. It is intended for field personnel, data users, laboratory sample reception personnel, analysts, and managers. 4.4 To obtain a representative subsample, layer analysis, grinding, mixing, and changing the physical state such as digesting, drying, melting or freezing may be required. This guide considers cone and quartering, riffle splitting, and particle size reduction. |
||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||
1.1 This guide covers common techniques for obtaining representative subsamples from a sample received at a laboratory for analysis. These samples may include solids, sludges, liquids, or multilayered liquids (with or without solids). 1.2 The procedures and techniques discussed in this guide depend upon the sample matrix, the type of sample preparation and analysis performed, the characteristic(s) of interest, and the project specific instructions or data quality objectives. 1.3 This guide includes several sample homogenization techniques, including mixing and grinding, as well as information on how to obtain a specimen or split laboratory samples. 1.4 This guide does not apply to air or gas sampling. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Historical
1.12.2010
Historical
1.5.2010
Historical
15.11.2009
Historical
1.2.2011
Historical
1.2.2011
Historical
1.9.2010
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-02 (Number of items: 2 210 389)
© Copyright 2024 NORMSERVIS s.r.o.