We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Determination of Trace Metals in Petroleum Coke by Wavelength Dispersive X-Ray Fluorescence Spectroscopy
STANDARD published on 1.7.2010
Designation standards: ASTM D6376-10
Note: WITHDRAWN
Publication date standards: 1.7.2010
SKU: NS-34879
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
alpha , aluminum, calcined petroleum coke, calcium, green petroleum coke, iron, manganese, nickel, petroleum coke, raw petroleum coke, silicon, sodium, spectrophotometry, sulfur, titanium, vanadium, X-ray fluorescence, Aluminum content, Calcined petroleum coke, Calcium content--petroleum products, Fuel sulfur, Green petroleum coke, Iron content--petroleum products, Vanadium content--petroleum products, Wavelength dispersive X-ray fluorescence (WDXRF), Manganese content--petroleum products
Significance and Use | ||||||||||||||||
The presence and concentration of sulfur and various metallic elements in a petroleum coke are major factors determining the suitability of a coke for various purposes. This test method provides rapid means for measuring sulfur and commercially important metallic elements in coke samples. This test method provides a guide for determining conformance to material specifications for use by buyers and sellers in a commercial transfer of petroleum coke. Sulfur contents can be used to evaluate the potential formation of sulfur oxides (SOx), a source of atmospheric pollution. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the X-ray fluorescence spectrometric determination of total sulfur and trace metals in samples of raw or calcined petroleum coke. Elements determined using this test method are listed in Table 1. 1.2 Detection limits, sensitivity, and optimal element ranges will vary with matrices, spectrometer type, analyzing crystal, and other instrument conditions and parameters. 1.3 All analytes are determined as the element and reported as such. These include all elements listed in Table 1. This test method may be applicable to additional elements or concentration ranges if sufficient standards are available to produce proper calibration equations. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historical
1.9.2012
Historical
1.5.2010
Historical
1.10.2013
Historical
1.5.2010
Historical
1.6.2013
Historical
1.11.2011
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.