Standard Test Method for Determination of Trace Metals in Petroleum Coke by Wavelength Dispersive X-ray Fluorescence Spectroscopy (Includes all amendments and changes 2/22/2017).
Translate name
STANDARD published on 1.1.2017
Designation standards: ASTM D6376-10(2017)e1
Publication date standards: 1.1.2017
SKU: NS-676310
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
alpha, aluminum, calcined petroleum coke, calcium, green petroleum coke, iron, manganese, nickel, petroleum coke, raw petroleum coke, silicon, sodium, spectrophotometry, sulfur, titanium, vanadium, X-ray fluorescence,, ICS Number Code 75.160.10 (Solid fuels)
Significance and Use | ||||||||||||||||
5.1 The presence and concentration of sulfur and various metallic elements in a petroleum coke are major factors determining the suitability of a coke for various purposes. This test method provides rapid means for measuring sulfur and commercially important metallic elements in coke samples. 5.2 This test method provides a guide for determining conformance to material specifications for use by buyers and sellers in a commercial transfer of petroleum coke. 5.3 Sulfur contents can be used to evaluate the potential formation of sulfur oxides (SO1.1 This test method covers the X-ray fluorescence spectrometric determination of total sulfur and trace metals in samples of raw or calcined petroleum coke. Elements determined using this test method are listed in Table 1. 1.2 Detection limits, sensitivity, and optimal element ranges will vary with matrices, spectrometer type, analyzing crystal, and other instrument conditions and parameters. 1.3 All analytes are determined as the element and reported as such. These include all elements listed in Table 1. This test method may be applicable to additional elements or concentration ranges if sufficient standards are available to produce proper calibration equations. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|