Standard Test Method for Determining Connection Strength Between Geosynthetic Reinforcement and Segmental Concrete Units (Modular Concrete Blocks)
STANDARD published on 1.6.2011
Designation standards: ASTM D6638-11
Note: WITHDRAWN
Publication date standards: 1.6.2011
SKU: NS-35973
The number of pages: 7
Approximate weight : 21 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
connections, geogrid, geosynthetic, geosynthetic reinforcement, geotextile, performance test, segmental concrete units, tensile test, ICS Number Code 91.100.50 (Binders. Sealing materials)
Significance and Use | ||||||||||
The connection strength between geosynthetic reinforcement and segmental concrete block units is used in design of reinforced soil retaining walls. This test is used to determine the connection strength for the design of the connection system formed by segmental concrete block units and geosynthetic reinforcement layers in reinforced soil retaining walls. Performing a series of these connection tests at varying normal loads permits development of a relationship between connection strength and normal load. This relationship may be linear, bi-linear, or some other complex mathematical expression. This connection strength test is meant to be a performance test (laboratory or field), therefore, it should be conducted using full-scale system components. The conditions for the test are selected by the user and are not for routine testing. As a performance test on full-scale system components it accounts for some of the variables in construction procedures and materials tolerance normally present for these types of retaining wall systems. |
||||||||||
1. Scope | ||||||||||
1.1 This test method is used to determine the connection properties between a layer of geosynthetic reinforcement and segmental concrete block units used in construction of reinforced soil retaining walls. The test is carried out under conditions determined by the user that reproduce the connection system at full-scale. The results of a series of tests are used to define a relationship between connection strength for a segmental unit-geosynthetic connection system and normal load. 1.2 This is a performance test used to determine properties for design of retaining wall systems utilizing segmental concrete units and soil reinforcing geosynthetics, either geotextiles or geogrids. The test is performed on a full-scale construction of the connection and may be run in a laboratory or the field. 1.3 The values stated in SI units are regarded as the standard. The values stated in inch-pound units are provided for information only. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.1.2009
Historical
1.6.2011
Historical
1.5.2014
Historical
15.7.2014
Historical
1.12.2010
Historical
1.6.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.