We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Determination of Parent and Alkyl Polycyclic Aromatics in Sediment Pore Water Using Solid-Phase Microextraction and Gas Chromatography/Mass Spectrometry in Selected Ion Monitoring Mode (Includes all amendments And changes 12/23/2021).
Automatically translated name:
Standard Test Method for Determination of Parent and Alkyl Polycyclic Aromatics in Sediment Pore Water Using Solid-Phase Microextraction and Gas Chromatography/Mass Spectrometry in Selected Ion Monitoring Mode
STANDARD published on 17.5.2013
Designation standards: ASTM D7363-13a
Note: WITHDRAWN
Publication date standards: 17.5.2013
SKU: NS-38283
The number of pages: 26
Approximate weight : 78 g (0.17 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
ICS Number Code 13.080.10 (Chemical characteristics of soil)
Significance and Use | |||||
5.1 This method directly determines the concentrations of dissolved PAH concentrations in environmental sediment pore water samples. The method is important from an environmental regulatory perspective because it can achieve the analytical sensitivities to meet the goals of the USEPA narcosis model for protecting benthic organisms in PAH contaminated sediments. Regulatory methods using solvent extraction have not achieved the wide calibration ranges from nanograms to milligrams per litre and the required levels of detection in the nanogram-per-litre range. In addition, conventional solvent extraction methods require large aliquot volumes (litre or larger), use of large volumes of organic solvents, and filtration to generate the pore water. This approach entails the storage and processing of large volumes of sediment samples and loss of low molecular weight PAHs in the filtration and solvent evaporation steps. 5.2 This method can be used to determine nanogram to milligram per litre PAH concentrations in pore water. Small volumes of pore water are required for SPME extraction, only 1.5 mL per determination and virtually no solvent extraction waste is generated. |
|||||
1. Scope | |||||
1.1 The U.S. Environmental Protection Agency (USEPA) narcosis model for benthic organisms in sediments contaminated with polycyclic aromatic hydrocarbons (PAHs) is based on the concentrations of dissolved PAHs in the interstitial water or “pore water” in sediment. This test method covers the separation of pore water from PAH-impacted sediment samples, the removal of colloids, and the subsequent measurement of dissolved concentrations of the required 10 parent PAHs and 14 groups of alkylated daughter PAHs in the pore water samples. The “24 PAHs” are determined using solid-phase microextraction (SPME) followed by Gas Chromatography/Mass Spectrometry (GC/MS) analysis in selected ion monitoring (SIM) mode. Isotopically labeled analogs of the target compounds are introduced prior to the extraction, and are used as quantification references. 1.2 Lower molecular weight PAHs are more water soluble than higher molecular weight PAHs. Therefore, USEPA-regulated PAH concentrations in pore water samples vary widely due to differing saturation water solubilities that range from 0.2 µg/L for indeno[1,2,3-cd]pyrene to 31 000 µg/L for naphthalene. This method can accommodate the measurement of microgram per litre concentrations for low molecular weight PAHs and nanogram per litre concentrations for high molecular weight PAHs. 1.3 The USEPA narcosis model predicts toxicity to benthic organisms if the sum of the toxic units (ΣTU Analyte |
Added d-PAH |
d-PAH Internal |
Conc. for One Performance Limit |
Basis for |
|
Naphthalene |
A |
A |
193.47 |
5.69 |
B |
2-Methylnaphthalene |
|
B |
81.69 |
2.40 |
B |
1-Methylnaphthalene |
B |
B |
81.69 |
2.40 |
B |
C2-Naphthalenes |
|
A |
30.24 |
0.89 |
B |
C3-Naphthalenes |
|
A |
11.10 |
0.33 |
B |
C4-Naphthalenes |
|
A |
4.05 |
0.12 |
C |
Acenaphthylene |
|
C |
308.85 |
9.03 |
B |
Acenaphthene |
C |
C |
55.85 |
1.64 |
B |
Fluorene |
D |
D |
39.30 |
1.16 |
B |
C1-Fluorenes |
|
D |
13.99 |
0.41 |
B |
C2-Fluorenes |
|
D |
5.30 |
0.16 |
B |
C3-Fluorenes |
|
D |
1.92 |
0.06 |
S |
Phenanthrene |
E |
E |
19.13 |
0.56 |
B |
Anthracene |
|
E |
20.72 |
0.61 |
B |
C1-Phenanthrenes/Anthracenes |
|
E |
7.44 |
0.22 |
B |
C2-Phenanthrenes/Anthracenes |
|
E |
3.20 |
0.09 |
B |
C3-Phenanthrenes/Anthracenes |
|
E |
1.26 |
0.04 |
B |
C4-Phenanthrenes/Anthracenes |
|
E |
0.56 |
0.02 |
S |
Fluoranthene |
|
F |
7.11 |
0.21 |
B |
Pyrene |
F |
F |
10.11 |
0.30 |
B |
C1-Fluoranthenes/Pyrenes |
|
F |
4.89 |
0.14 |
C |
Benz[a]anthracene |
|
G |
2.23 |
0.066 |
B |
Chrysene |
G |
G |
2.04 |
0.060 |
B |
C1-Chrysenes/Benz[a]anthracenes |
|
G |
0.86 |
0.025 |
C |
1.6 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Practice for Dealing With
Outlying Observations Standard Practices for Sampling Water
from Flowing Process Streams Standard Practice for Determination of
Precision and Bias of Applicable Test Methods of Committee D19 on
Water Standard Guide for Equipment for Sampling
Water and Steam in Closed Conduits (Withdrawn 2003) Standard Specification for Reagent
Water
Historical
1.7.2007
Historical
1.11.2013
Historical
1.1.2013
Historical
1.11.2006
Historical
15.6.2010
Historical
1.7.2009
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.