We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Establishing the Competence of Laboratories Using ASTM Procedures in the Sampling and Analysis of Coal and Coke (Withdrawn 2024)
Automatically translated name:
Standard Practice for Establishing the Competence of Laboratories Using ASTM Procedures in the Sampling and Analysis of Coal and Coke
STANDARD published on 1.3.2016
Designation standards: ASTM D7448-16
Note: WITHDRAWN
Publication date standards: 1.3.2016
SKU: NS-636758
The number of pages: 8
Approximate weight : 24 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
accuracy, competence, evaluation, laboratory, management, stability,, ICS Number Code 75.160.10 (Solid fuels)
Significance and Use | ||||||||||||||||||||||
3.1 International standard ANSI/ISO/IEC 17025 promotes the use of documented accountability and quality control procedures to assure a laboratory and its clients that the laboratory can produce technically valid data and results in the routine performance of its sampling, sample preparation and testing activities. 3.2 A laboratory shall use ANSI/ISO/IEC 17025 to develop its quality system. Clause 4 of ANSI/ISO/IEC 17025 specifies the requirements for sound management. Clause 5 of ANSI/ISO/IEC 17025 specifies the requirements for technical competence for the type of tests or calibrations, or both the laboratory undertakes. 3.3 In addition to complying with the requirements of ANSI/ISO/IEC 17025, the Annex of this standard practice contains information that shall be considered important for the evaluation and operation of a competent Coal and Coke sampling or testing facility, or both. The information in this Annex is presented where it is not otherwise covered in ANSI/ISO/IEC 17025 or the applicable ASTM methods. 3.4 Laboratory clients, regulatory authorities, and accreditation bodies that recognize the competence of testing and calibration laboratories can use this standard practice as the basis for their evaluation. 3.5 The primary significance of this practice is to establish that for a laboratory to generate measurements traceable to SI units, it must: 3.5.1 Have a clear understanding of the work requested by the client. 3.5.2 Meet the quality system requirements of the internationally accepted ANSI/ISO/IEC 17025 standard. 3.5.3 Use test methods which have been shown to be traceable to SI units of measurement. 3.5.4 Be able to demonstrate that the laboratory is in statistical control at the time the measurements are made. |
||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||
1.1 This practice specifies requirements to operate and evaluate the quality and management systems in a laboratory that provides services with respect to sample collection, sample preparation, or testing of coal, coke, and ash derived from coal or coke using ASTM standards that are under the jurisdiction of Committee D05 on Coal and Coke. Note 1: The word “laboratory” is used throughout this practice
when referring to an organization that provides services in coal
sampling or testing, or both. It is recognized, however, that the
word may not be appropriate to an organization that does not
perform actual laboratory sample testing.
1.2 International standard ANSI/ISO/IEC 17025 shall be the governing document specifying requirements for management, technical competence and evaluation of a laboratory. Note 2: An accrediting body or user of laboratory services can
also impose technical or non-technical requirements not
specifically addressed in ANSI/ISO/IEC 17025 provided they do not
invalidate the requirements of ANSI/ISO/IEC 17025.
1.3 This practice is used to evaluate only those capabilities specifically claimed by a laboratory. 1.4 All percentages are percent mass fractions unless otherwise noted. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-21 (Number of items: 2 206 478)
© Copyright 2024 NORMSERVIS s.r.o.