Standard Test Method for Determination of Nonylphenol, p-tert-Octylphenol, Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters by Liquid Chromatography/Tandem Mass Spectrometry
STANDARD published on 1.3.2009
Designation standards: ASTM D7485-09
Note: WITHDRAWN
Publication date standards: 1.3.2009
SKU: NS-38583
The number of pages: 10
Approximate weight : 30 g (0.07 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
diethoxylate, liquid chromatography, monoethoxylate, nonylphenol, octylphenol, solid phase extraction, tandem mass spectrometry, water, ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||||||||||
NP and OP have been shown to have toxic effects in aquatic organisms. The source of NP and OP is prominently from the use of common commercial surfactants. The most widely used surfactant is nonylphenol ethoxylate (NPEO) which has an average ethoxylate chain length of nine. The ethoxylate chain is readily biodegraded to form NP1EO, NP2EO, nonylphenol carboxylate (NPEC) and, under anaerobic conditions, NP. NP will also biodegrade, but may be released into environmental waters directly at trace levels. This method has been investigated and is applicable for environmental waters, including seawater. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the determination of nonylphenol (NP), nonylphenol ethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), and octylphenol (OP), extracted from water utilizing solid phase extraction (SPE), separated using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). These compounds are qualitatively and quantitatively determined by this method. This method adheres to single reaction monitoring (SRM) mass spectrometry. 1.2 The method detection limit (MDL) and reporting limit (RL) for NP, NP1EO, NP2EO, and OP are listed in Table 1. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 MDL and Reporting Limits
A MDL Determined Following The Code of Federal Regulations, 40 CFR Part 136, Appendix B. B Lowest Point of the Reporting Range is Calculated from the LV 1 Concentration Calibration Standard in Table 4. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historical
1.12.2009
Historical
1.12.2009
Historical
1.12.2009
Historical
1.6.2010
Historical
1.1.2014
Historical
1.2.2011
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.