We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Acoustic Emission Examination of Fiberglass Reinforced Plastic Resin (FRP) Tanks/Vessels
STANDARD published on 1.7.2011
Designation standards: ASTM E1067/E1067M-11
Note: WITHDRAWN
Publication date standards: 1.7.2011
SKU: NS-40324
The number of pages: 16
Approximate weight : 48 g (0.11 lbs)
Country: American technical standard
Category: Technical standards ASTM
Noise emitted by machines and equipmentStationary containers and tanks
Keywords:
felicity effect, felicity ratio, fiber debonding, fiber pullout, resin cracking, source characterization, source location, Acoustic emission (AE) testing--plastics, Containers--tank cars/wagons, Fiberglass-reinforced plastics (FRP), Glass-fiber-reinforced (GRP) plastics, Pressure testing--plastics, Pressure vessel plastic, Resins, Tanks, Vacuum testing, ICS Number Code 17.140.20 (Noise emitted by machines and equipment), 23.020.10 (Stationary containers and tanks)
Significance and Use | ||||||||||||||||||||
The AE examination method detects damage in FRP equipment. The damage mechanisms that are detected in FRP are as follows: resin cracking, fiber debonding, fiber pullout, fiber breakage, delamination, and bond failure in assembled joints (for example, nozzles, manways, etc.). Flaws in unstressed areas and flaws that are structurally insignificant will not generate AE. This practice is convenient for on-line use under operating stress to determine structural integrity of in-service equipment usually with minimal process disruption. Indications located with AE should be examined by other techniques; for example, visual, ultrasound, dye penetrant, etc., and may be repaired and tested as appropriate. Repair procedure recommendations are outside the scope of this practice. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This practice covers acoustic emission (AE) examination or monitoring of fiberglass-reinforced plastic (FRP) tanks-vessels (equipment) under pressure or vacuum to determine structural integrity. 1.2 This practice is limited to tanks-vessels designed to operate at an internal pressure no greater than 1.73 MPa absolute [250 psia] above the static pressure due to the internal contents. It is also applicable for tanks-vessels designed for vacuum service with differential pressure levels between 0 and 0.10 MPa [0 and 14.5 psi]. 1.3 This practice is limited to tanks-vessels with glass contents greater than 15 % by weight. 1.4 This practice applies to examinations of new and in-service equipment. 1.5 Units—The values stated in either SI units or inch-pound units are to be regarded as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (For more specific safety precautionary information see 8.1.) |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Historical
1.6.2013
Historical
1.4.2009
Historical
15.6.2012
Historical
1.1.2010
Historical
15.6.2012
Historical
1.8.2014
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.