Standard Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration With Activated Charcoal
STANDARD published on 1.6.2012
Designation standards: ASTM E1412-12
Note: WITHDRAWN
Publication date standards: 1.6.2012
SKU: NS-41672
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
fire debris samples, passive headspace concentration, ICS Number Code 13.220.99 (Other standards related to fire protection)
Significance and Use | ||||||||||||||||
This practice is useful for preparing extracts from fire debris for later analysis by gas chromatography mass spectrometry. This is a very sensitive separation procedure, capable of isolating quantities smaller than 1/10 μL of ignitable liquid residue from a sample. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice describes the procedure for separation of small quantities of ignitable liquid residues from samples of fire debris using an adsorbent material to extract the residue from the static headspace above the sample, then eluting the adsorbent with a solvent. 1.2 While this practice is suitable for successfully extracting ignitable liquid residues over the entire range of concentration, the headspace concentration methods are best used when a high level of sensitivity is required due to a very low concentration of ignitable liquid residues in the sample. 1.2.1 Unlike other methods of separation and concentration, this practice is essentially nondestructive. 1.3 Alternate separation and concentration procedures are listed in the referenced documents (see Practices E1386, E1388, E1413, and E2154). 1.4 This practice does not replace knowledge, skill, ability, experience, education, or training and should be used in conjunction with professional judgment. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historical
1.4.2012
Historical
1.5.2014
Historical
1.7.2013
Historical
1.7.2013
Historical
1.5.2013
Historical
1.9.2008
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.