Standard Practice for Determining Steady State Thermal Transmittance of Fenestration Systems
STANDARD published on 1.4.2014
Designation standards: ASTM E1423-14
Note: WITHDRAWN
Publication date standards: 1.4.2014
SKU: NS-41715
The number of pages: 12
Approximate weight : 36 g (0.08 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
doors, fenestration, heat, heat transfer, hot box, skylight, steady state, surround panel, thermal performance, transmittance, U-factor, windows, ICS Number Code 91.060.50 (Doors and windows),91.120.10 (Thermal insulation of buildings)
Significance and Use | ||||||||||||||||||
4.1 This practice details the test specimen sizes and test conditions, namely, the room-side and weather-side air temperatures, and the surface heat transfer coefficients for both sides of the test specimen, when testing fenestration products in accordance with Test Method C1199. 4.2 The thermal transmittance and conductance of a specimen are affected by its size and three-dimensional geometry. Tests should therefore be conducted using the specimen sizes recommended in 5.1. Should the specimen size differ from those given in 4.3 Many factors can affect the thermal performance of a fenestration system, including deflections of sealed glazing units. Care should be exercised to maintain the original physical condition of the fenestration system and while installing it in the surround panel. 4.4 The thermal transmittance and conductance results obtained do not, and are not intended, to reflect performances expected from field installations since they do not account for solar radiation and air leakage effects. The thermal transmittance and conductance results are taken from specified laboratory conditions and are to be used only for fenestration product comparisons and as input to thermal performance analyses that also include solar and air leakage effects. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice covers standard test specimen sizes and test conditions as well as the calculation and presentation of the thermal transmittance and conductance data measured in accordance with Test Method C1199. The standard sizes and conditions are to be used for fenestration product comparison purposes. The specifier may choose other sizes and conditions for product development or research purposes. 1.2 This practice deals with the determination of the thermal properties of a fenestration system installed vertically without the influences of solar heat gain and air leakage effects. 1.3 This practice specifies the
procedure for determining the standardized thermal transmittance of
a fenestration test specimen using specified values of the
room-side and weather-side surface heat transfer coefficients,
hh and
hc,
respectively.
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historical
1.10.2012
Historical
15.4.2014
Historical
1.2.2014
Historical
1.5.2014
Historical
1.5.2014
Historical
1.12.2011
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.