We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Electromagnetic Examination of Ferromagnetic Steel Wire Rope
STANDARD published on 1.12.2006
Designation standards: ASTM E1571-06
Note: WITHDRAWN
Publication date standards: 1.12.2006
SKU: NS-42228
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
electromagnetic examination, flux leakage, local flaws (LF), magnetic flux, magnetic flux leakage, percent loss of metallic cross-sectional area (LMA), rod reference standards, sensor head, wire rope, wire rope reference standard, ICS Number Code 77.040.20 (Non-destructive testing of metals)
Significance and Use | ||||||||||||
This practice outlines a procedure to standardize an instrument and to use the instrument to examine ferromagnetic wire rope products in which the electromagnetic, magnetic flux, magnetic flux leakage, or any combination of these methods is used. If properly applied, the electromagnetic and the magnetic flux methods are capable of detecting the presence, location, and magnitude of metal loss from wear and corrosion, and the magnetic flux leakage method is capable of detecting the presence and location of flaws such as broken wires and corrosion pits. The instrument’response to the rope’fabrication, installation, and in-service-induced flaws can be significantly different from the instrument’response to artificial flaws such as wire gaps or added wires. For this reason, it is preferable to detect and mark (using set-up standards that represent) real in-service-induced flaws whose characteristics will adversely affect the serviceability of the wire rope. |
||||||||||||
1. Scope | ||||||||||||
1.1 This practice covers the application and standardization of instruments that use the electromagnetic, the magnetic flux, and the magnetic flux leakage examination method to detect flaws and changes in metallic cross-sectional areas in ferromagnetic wire rope products. 1.1.1 This practice includes rope diameters up to 2.5 in. (63.5 mm). Larger diameters may be included, subject to agreement by the users of this practice. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-07-18 (Number of items: 2 337 971)
© Copyright 2024 NORMSERVIS s.r.o.