We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Guide for Elemental Analysis by Wavelength Dispersive X-Ray Fluorescence Spectrometry
Translate name
STANDARD published on 15.6.2022
Designation standards: ASTM E1621-22
Publication date standards: 15.6.2022
SKU: NS-1066083
The number of pages: 9
Approximate weight : 27 g (0.06 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
calibration, interferences, line overlap, spectrometry, X-ray, X-ray fluorescence,, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||||||
5.1?X-ray fluorescence spectrometry can provide an accurate determination of metallic and many non-metallic elements in a wide variety of solid and liquid materials. This guide covers the information that should be included in an X-ray spectrometric analytical method and provides direction to the user for determining the optimum conditions needed to achieve acceptable accuracy. 5.2?The accuracy of a determination is a function of the calibration algorithm, the sample preparation, and the sample homogeneity. Close attention to all aspects of these areas is necessary to achieve acceptable results. 5.3?All concepts discussed in this guide are explored in detail in a number of published texts and in the scientific literature. |
||||||||||||
1. Scope | ||||||||||||
1.1?This standard provides guidelines for developing and describing analytical procedures using a wavelength dispersive X-ray spectrometer for elemental analysis of solid metals, ores, and related materials. Material forms discussed herein include solids, powders, and solid forms prepared by chemical and physical processes such as borate fusion and pressing of briquettes. 1.2?Liquids are not discussed in this guide because they are much less frequently encountered in metals and mining laboratories. However, aqueous liquids can be processed by borate fusion to create solid specimens, and X-ray spectrometers can be equipped to handle liquids directly. 1.3?Some provisions of this guide may be applicable to the use of an energy dispersive X-ray spectrometer. 1.4?UnitsThe values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.