We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Specification for Air Barrier (AB) Material or System for Low-Rise Framed Building Walls
STANDARD published on 1.9.2011
Designation standards: ASTM E1677-11
Note: WITHDRAWN
Publication date standards: 1.9.2011
SKU: NS-42606
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
air barrier, air exfiltration, air infiltration, air leakage, air leakage rate, opaque wall, structural integrity, vapor retarder, water leakage, water resistance, water vapor permeance: Air infiltration/exfiltration, Air leakage testing--building materials/constructions, Air retarder (AR) systems, Architectural materials/applications--specifications, Building materials/applications--specifications, Opaque wall, Structural building materials/applications--specifications, Structural integrity
1. Scope | ||||||||||||||||||||||
1.1 This specification covers minimum performances and specification criteria for an air barrier (AB) material or system for framed walls of low-rise buildings. The intended users are purchasers of the AB, specifiers of the AB and regulatory groups. The provisions contained in this specification are intended to allow the user to design the wall performance criteria and increase AB specifications to accommodate a particular climate location, function, or design of the intended building. Air barrier performance and specification minimums were selected with the service life of the building wall in mind. 1.2 This specification focuses on ABs for opaque walls. Other areas of the exterior envelope, such as roofs, floors, and interfaces between these areas are not included in this specification. 1.3 This specification does not address air leakage into the wall cavity, that is, windwashing. No standardized test has been developed that adequately identifies all of the influencing factors and measures the impact of this effect on the wall's thermal performance. 1.4 The specifications in this standard are not intended to be utilized for energy load calculations and are not based on an expected level of energy consumption. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 The following safety hazards caveat pertains only to the test method portion, Annex A1, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.