Standard Test Method for Determining Relative Image Quality of Industrial Radiographic Film Exposed to X-Radiation from 4 to 25 MeV
STANDARD published on 1.6.2014
Designation standards: ASTM E1735-07(2014)
Note: WITHDRAWN
Publication date standards: 1.6.2014
SKU: NS-42828
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
EPS, film, IQI, radiation, radiographic, X-ray, ICS Number Code 37.040.20 (Photographic paper, film and plates. Cartridges)
Significance and Use | ||||||||||
4.1 This test method provides a test for determining the relative image quality response of radiographic film when exposed to 4 to 25 MeV X rays as any single component of the total X-ray system (for example, screens) is varied. By holding the technique parameters (except exposure time) and processing parameters constant, the image quality response of radiographic film may be evaluated on a relative basis. 4.2 Alternately, this test method provides a test for measuring the image quality of the X-ray system or any component of the system. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers determination of the relative image quality response of industrial radiographic film when exposed to X-radiation sources having photon energies from 4 to 25 MeV. Evaluation of the film is based on the visibility of holes in a special image quality indicator (IQI). Since results for a given film type may vary, depending on the particular processing system and processing conditions used, it is essential to state the exposure parameters and achieved density, processing chemistry, processing cycle, and processing temperature. For the purposes of this test method, it is assumed that all components of the X-ray system are operating properly and are capable of producing a given image quality. This test method is not intended to be used for films exposed with Cobalt 60 sources or X-ray sources below 4 MeV. 1.2 The values stated in either SI or inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.11.2011
Historical
1.11.2011
Historical
1.11.2011
Historical
1.10.2012
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-09-27 (Number of items: 2 350 600)
© Copyright 2024 NORMSERVIS s.r.o.