We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Visual Inspections of Photovoltaic Modules
STANDARD published on 1.12.2012
Designation standards: ASTM E1799-12
Note: WITHDRAWN
Publication date standards: 1.12.2012
SKU: NS-43077
The number of pages: 2
Approximate weight : 6 g (0.01 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
energy, inspections, modules, photovoltaics, solar, testing, visual, ICS Number Code 27.160 (Solar energy engineering)
Significance and Use | ||
4.1 Environmental stress tests, such as those listed in 4.2 Effects of environmental stress testing may vary from no effects to significant changes. Some physical changes in the module may be visible when there are no measurable electrical changes. Similarly, electrical changes in the module may occur with no visible changes. 4.3 It is the intent of this practice to provide a recognized procedure for performing visual inspections and to specify effects that should be reported. 4.4 Many of these effects are subjective. In order to determine if a module has passed a visual inspection, the user of this practice must specify what changes or conditions are acceptable. The user may have to judge whether changes noted during an inspection will limit the useful life of a module design. |
||
1. Scope | ||
1.1 This practice covers procedures and criteria for visual inspections of photovoltaic modules. 1.2 Visual inspections of photovoltaic modules are normally performed before and after modules have been subjected to environmental, electrical, or mechanical stress testing, such as thermal cycling, humidity-freeze cycling, damp heat exposure, ultraviolet exposure, mechanical loading, hail impact testing, outdoor exposure, or other stress testing that may be part of photovoltaic module testing sequence. 1.3 This practice does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this practice. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Historical
1.4.2009
Historical
1.6.2010
Historical
1.6.2010
Historical
1.12.2012
Historical
15.1.2009
Historical
1.4.2009
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-15 (Number of items: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.