Standard Practice for Controlling Quality of Radiological Examination by Using Representative Quality Indicators (RQIs)
STANDARD published on 1.6.2014
Designation standards: ASTM E1817-08(2014)
Note: WITHDRAWN
Publication date standards: 1.6.2014
SKU: NS-43156
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
radiologic images, representative quality indicator, RQI, ICS Number Code 19.100 (Non-destructive testing),77.040.20 (Non-destructive testing of metals)
Significance and Use | ||||||||||||||||||
5.1 The use of RQIs is a significant departure from normal practice in industrial radiology because it is not a standard design and is dependent on the application, material, and process and therefore cannot be a simple plaque or wire. The use of an RQI provides documented evidence that radiologic images have the level of quality necessary to reveal those nonconformances for which the parts are being examined by ensuring adequate spatial resolution and contrast sensitivity in the areas of interest. 5.2 Where conventional IQIs conforming to Practice E747 or E1025 can be used effectively, those practices should be followed. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice covers the radiological examination of unique materials or processes, or both, for which conventionally designed image quality indicators (IQIs), such as those described in Practices E747 and E1025, may be inadequate in controlling the quality and repeatability of the radiological image. 1.2 Where appropriate, representative image quality indicators (RQIs) may also represent criteria levels of the acceptance or rejection of images of discontinuities. 1.3 This practice is applicable to most radiological methods of examination. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historical
1.12.2013
Historical
1.7.2009
Historical
1.9.2010
Historical
15.10.2012
Historical
1.12.2011
Historical
1.11.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.