We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Guide for Forensic Analysis of Fibers by Infrared Spectroscopy
STANDARD published on 15.9.2010
Designation standards: ASTM E2224-10
Note: WITHDRAWN
Publication date standards: 15.9.2010
SKU: NS-44711
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
fibers, forensic science, infrared spectrophotometry, Sulfar fibers, UV comparison microscopy, Vinal fibers, Vinyon fibers, Forensic investigation/analysis, FTIR analysis, Infrared spectrophotometry, Infrared spectroscopy, Lastrile fibers, Microscopical infrared analysis, Novoloid fibers, Nytril fibers, Polycarbonate fibers, Fluorocarbon fibers, Acrylic fibers, Anidex fibers, Fiber analysis, ICS Number Code 07.140 (Forensic science), 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||
Fiber samples may be prepared and mounted for microscopical infrared analysis by a variety of techniques. Infrared spectra of fibers are obtained using an IR spectrophotometer coupled with an IR microscope. Fiber polymer identification is made by comparison of the fiber spectrum with reference spectra. Consideration should be given to the potential for additional compositional information that may be obtained by IR spectroscopy over polarized light microscopy alone (see Microscopy Guidelines). The extent to which IR spectral comparison is indicated will vary with specific sample and case evaluations. The recommended point for IR analysis in a forensic fiber examination is following visible and ultraviolet (UV) comparison microscopy (fluoresence microscopy), polarized light microscopy, and UV/visible spectroscopy, but before dye extraction for thin-layer chromatography. This list of analytical techniques is not meant to be totally inclusive or exclusive. The following generic types of fiber are occasionally encountered in routine forensic examinations: Anidel, Fluorocarbon, Lastrile, Novoloid, Nytril, Polycarbonate, PBI, Sulfar, Vinal, and Vinyon. Exemplar data, reference standards, or examiner experience, or combination thereof, may be inadequate for characterization of these fibers by optical microscopical and microchemical techniques. For these fiber types, IR spectroscopic confirmation of polymer type is advisable. Because of the large number of subgeneric classes, forensic examination of acrylic fibers is likely to benefit significantly from IR spectral analysis (11). Colorless manufactured fibers are lacking in the characteristics for color comparison available in dyed or pigmented fibers. The forensic examination of these fibers may, therefore, benefit from the additional comparative aspect of IR spectral analysis. If polymer identification is not readily apparent from optical data alone, an additional method of analysis should be used such as microchemical tests, melting point, pyrolysis infrared spectrophotometry, or pyrolysis gas chromatography. Infrared analysis offers the advantage of being the least destructive of these methods (12). |
||||||||
1. Scope | ||||||||
1.1 Infrared (IR) spectrophotometery is a valuable method of fiber polymer identification and comparison in forensic examinations. The use of IR microscopes coupled with Fourier transform infrared (FT-IR) spectrometers has greatly simplified the IR analysis of single fibers, thus making the technique feasible for routine use in the forensic laboratory. 1.2 This guideline is intended to assist individuals and laboratories that conduct forensic fiber examinations and comparisons in the effective application of infrared spectroscopy to the analysis of fiber evidence. Although this guide is intended to be applied to the analysis of single fibers, many of its suggestions are applicable to the infrared analysis of small particles in general. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. |
||||||||
2. Referenced Documents | ||||||||
|
Historical
1.1.2012
Historical
1.5.2013
Historical
1.12.2012
Historical
1.9.2008
Historical
1.2.2014
Historical
1.9.2009
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.