Standard Guide for Assessment of Antimicrobial Activity Using a Time-Kill Procedure
STANDARD published on 1.4.2008
Designation standards: ASTM E2315-03(2008)
Note: WITHDRAWN
Publication date standards: 1.4.2008
SKU: NS-45014
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
antimicrobial, in vitro, log10 reduction, percent reduction, time-kill, Aerobic/anaerobic biodegradation, Antimicrobial formulations/testing, Inoculum processing, Log 10 reduction, Microbial environments, Percent bacterial reduction, Reduction, in vitro Evaluation, ICS Number Code 07.100.99 (Other standards related to microbiology)
Significance and Use | ||||||
This procedure may be used to assess the in vitro reduction of a microbial population of test organisms after exposure to a test material. |
||||||
1. Scope | ||||||
1.1 This guide covers examples of a basic method to measure the changes of a population of aerobic microorganisms within a specified sampling time when tested against antimicrobial test materials in vitro. Several options for organism selection and growth, inoculum preparation, sampling times and temperatures are provided. When the basic technique is performed as a specific test method it is critical when evaluating the results to ensure that such variables have been standardized. Antimicrobial activity of specific materials, as measured by this technique, may vary significantly depending on variables selected. It is important to understand the limitations of in vitro tests, especially comparisons of results from tests performed under different circumstances. As an example, test results of microorganisms requiring growth supplements, or special incubation conditions, may not be directly comparable to more robust organisms under the conditions of a single procedure. 1.2 Knowledge of microbiological techniques is required for this test. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historical
1.6.2014
Historical
1.10.2014
Historical
15.8.2012
Historical
1.9.2012
Historical
1.9.2012
Historical
1.9.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.