We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Specimen Preparation and Mounting of Reflective Insulation, Radiant Barrier and Vinyl Stretch Ceiling Materials for Building Applications to Assess Surface Burning Characteristics
STANDARD published on 1.1.2011
Designation standards: ASTM E2599-11
Note: WITHDRAWN
Publication date standards: 1.1.2011
SKU: NS-45700
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
fire, fire test, flame spread, insulation, radiant barrier, reflective insulation, reflective plastic core, smoke developed, Steiner tunnel, vinyl stretch ceiling material, Fire testing--building materials, Flame spread, Radiant barrier systems (RBS), Reflective insulation, Surface burning characteristics, Burning characteristics, ICS Number Code 13.220.50 (Fire-resistance of building materials and elements)
Significance and Use | ||||||||||||||||
Reflective insulation, radiant barrier and vinyl stretch ceiling materials are evaluated in accordance with Test Method E84 to comply with building or mechanical code requirements. This practice describes, in detail, a specimen mounting procedure for reflective insulation, radiant barrier and vinyl stretch ceiling materials. The material shall be representative of the materials used in actual field installations. Specimen preparation and mounting procedures for materials not described in this practice shall be added as the information becomes available. The limitations for this procedure are those associated with Test Method E84. This practice shall not apply to rigid foam plastics with or without reflective facers. This practice shall not apply to site-fabricated stretch systems covered by Practice E2573. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice describes a procedure for specimen preparation and mounting when testing reflective insulation, radiant barrier and vinyl stretch ceiling materials to assess flame spread and smoke development as surface burning characteristics using Test Method E84. 1.2 This practice is for reflective insulation materials and radiant barrier materials intended for mechanical fastening to substrates or building structural members, or intended to be mounted to a substrate with an adhesive. 1.3 Specimens of reflective insulation materials and radiant barrier materials intended for mechanical fastening shall be prepared and mounted in accordance with 6.1. Specimens of reflective insulation materials and radiant barrier materials intended to be mounted to a substrate with an adhesive shall be prepared and mounted in accordance with 6.2. If the reflective insulation material or sheet radiant barrier material includes manufacturer recommended installation instructions with the option to be installed either by mechanical attachment or adhered, the insulation material shall be tested by both mounting procedures as outlined in 6.1 and 6.2. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.