Standard Guide for Selection and Use of Wideband, Low Temperature Infrared Thermometers
STANDARD published on 1.5.2010
Designation standards: ASTM E2758-10
Note: WITHDRAWN
Publication date standards: 1.5.2010
SKU: NS-45988
The number of pages: 18
Approximate weight : 54 g (0.12 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
background radiation, blackbody, emissivity, field-of-view, handheld thermometer, infrared, infrared thermometer, IR gun, IR thermometer, laser thermometer, low temperature, non-contact thermometer, pyrometer, radiation thermometer, radiometer, reflected radiation, size-of-source effect, spot pyrometer, spot size, spot thermometer, temperature gun, temperature measurement, thermometry usage, wideband, ICS Number Code 17.200.20 (Temperature-measuring instruments)
Significance and Use | ||||||||||
This guide provides guidelines and basic test methods for the use of infrared thermometers. The purpose of this guide is to provide a basis for users of IR thermometers to make more accurate measurements, to understand the error in measurements and reduce the error in measurements. |
||||||||||
1. Scope | ||||||||||
1.1 This guide covers electronic instruments intended for measurement of temperature by detecting intensity of thermal radiation exchanged between the subject of measurement and the sensor. 1.2 The devices covered by this guide are referred to as IR thermometers. 1.3 The IR thermometers covered in this guide are instruments that are intended to measure temperatures below 1000 °C and measure a wide band of thermal radiation in the infrared region. 1.4 This guide covers best practice in using IR thermometers. It addresses concerns that will help the user make better measurements. It also provides graphical tables to help determine the accuracy of measurements. 1.5 Details on the design and construction of IR thermometers are not covered in this guide. 1.6 This guide does not cover medium- and high-temperature IR thermometry (above 1000 °C). It does not address the use of narrowband IR thermometers. 1.7 The values of quantities stated in SI units are to be regarded as the standard. The values of quantities in parentheses are not in SI and are optional. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||