Standard Test Method for Measuring Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb Temperatures)
STANDARD published on 1.10.2007
Designation standards: ASTM E337-02(2007)
Note: WITHDRAWN
Publication date standards: 1.10.2007
SKU: NS-46471
The number of pages: 24
Approximate weight : 72 g (0.16 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
aspiration, humidity, psychrometer, psychrometric table, temperature, vapor pressure, ventilation, wet-bulb temperature, ICS Number Code 07.060 (Geology. Meteorology. Hydrology)
1. Scope | ||||||||||||||||||||
1.1 General 1.1.1 This test method covers the determination of the humidity of atmospheric air by means of wet- and dry-bulb temperature readings. 1.1.2 This test method is applicable for meteorological measurements at the earth's surface, for the purpose of the testing of materials, and for the determination of the relative humidity of most standard atmospheres and test atmospheres. 1.1.3 This test method is also applicable when the temperature of the wet bulb only is required. In this case, the instrument comprises a wet-bulb thermometer only. 1.1.4 Relative humidity (RH) does not denote a unit. Uncertainties in the relative humidity are expressed in the form RH rh %, which means that the relative humidity is expected to lie in the range (RH rh) % to (RH + rh ) %, where RH is the observed relative humidity. All uncertainties are at the 95 % confidence level. 1.2 Method A- Psychrometer Ventilated by Aspiration: 1.2.1 This method incorporates the psychrometer ventilated by aspiration. The aspirated psychrometer is more accurate than the sling (whirling) psychrometer (see Method B), and it offers advantages in regard to the space which it requires, the possibility of using alternative types of thermometers (for example, electrical), easier shielding of thermometer bulbs from extraneous radiation, accidental breakage, and convenience. 1.2.2 This method is applicable within the ambient temperature range 5 to 80C, wet-bulb temperatures not lower than 1C, and restricted to ambient pressures not differing from standard atmospheric pressure by more than 30 %. 1.3 Method B- Psychrometer Ventilated by Whirling (Sling Psychrometer): 1.3.1 This method incorporates the psychrometer ventilated by whirling (sling psychrometer). 1.3.2 This method is applicable within the ambient temperature range 5 to 50C, wet-bulb temperatures not lower than 1C and restricted to ambient pressures not differing from standard atmospheric pressure by more than 30 %. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (For more specific safety precautionary statements, see 8.1 and 15.1 .)< |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-11-19 (Number of items: 2 206 144)
© Copyright 2024 NORMSERVIS s.r.o.