We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Evaluation of Microbicides Used in Cooling Water Systems
STANDARD published on 1.4.2013
Designation standards: ASTM E645-13
Note: WITHDRAWN
Publication date standards: 1.4.2013
SKU: NS-47493
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
algae, algicide, bacteria, bactericide, biofilms, cooling towers, cooling tower waters, deposits/slime, efficacy, fungi, fungicide, microbial biofouling, microbicide, ICS Number Code 65.100.99 (Other pesticides and agrochemicals)
Significance and Use | ||||||||||||||
5.1 This practice determines potentially effective microbicides for use in cooling water systems using cooling water and deposits/biofilm obtained from the field. The addition of deposits/biofilms addresses the need to include the major source of microorganisms in cooling water systems. Even with this addition, laboratory results may not be totally predictive of microbicidal effectiveness in the field. This is because conditions in the field affecting microbicide effectiveness are difficult to mimic in the laboratory. These conditions that affect microbicide efficacy include blow-down rate, addition of makeup water, water hardness, hydrocarbon leaks, pH, sediment loading, dissolved solids, microbes in slime (biofilms), and deposits (salts, iron minerals, organics, and so forth) on surfaces. An additional factor is the difficulty in enumerating all microbes in the water due to the lack of adequate recovery media. Guidelines that address formation of and testing for surface-attached microbes (biofilms) may be found in Guide E1427, while a guideline for unconventional measurement of microbes is found in Guide E1326. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice outlines a procedure for evaluating the efficacy of microbicides (algicides, bactericides, and fungicides) that will be used for controlling microbial growth in cooling water systems. The microbicides will be evaluated using simulated or real cooling tower water against (1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historical
1.11.2010
Historical
1.12.2012
Historical
1.10.2012
Historical
1.10.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-15 (Number of items: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.