Standard Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under Concentrated Static and Impact Loads
Translate name
STANDARD published on 1.10.2022
Designation standards: ASTM E661-22
Publication date standards: 1.10.2022
SKU: NS-1087644
The number of pages: 8
Approximate weight : 24 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
concentrated static load, deflection resistance, drop-bag tests, floor sheathing, impact load, roof sheathing, ultimate impact load, wood sheathing ,, ICS Number Code 79.040 (Wood, sawlogs and sawn timber),79.060.01 (Wood-based panels in general)
Significance and Use | ||||||||
5.1?The procedures outlined will provide data that can be used to evaluate the structural performance, under concentrated loads, of roof and floor sheathing, separate from the effects of the framing, under simulated conditions representative of those in actual service. 5.2?The procedures are intended to be applied to roof or floor sheathing materials installed directly to framing. They are not intended for the evaluation of the framed assembly as a whole. |
||||||||
1. Scope | ||||||||
1.1?This test method covers procedures for determining the resistance to deflection and damage of floor and roof sheathing used in site-built construction subjected to concentrated static loads as well as impact loads from nonrigid blunt objects. It is applicable to wood and wood-based panels and boards, but is not intended to cover profiled metal decks, nor precast or cast-in-place slabs. Surface indentation is not evaluated separately from deflection. 1.2?Three applications are covered: roof sheathing, subfloors, and single floors. Roof sheathing is tested in both a dry and a wet condition, while subfloors and single floors are both tested in a dry condition, as well as a condition of having dried out after being wet. These moisture conditions are those commonly experienced with site-built construction. Note 1:?Where it is anticipated that sheathing will be
subjected only to dry conditions during construction and use, or
else to greater moisture exposure than is indicated in 7.3.2, the corresponding exposure
conditions may be modified by agreement between the interested
parties. For example, shop-built construction may be tested dry
only, although the possibility of exposure to high humidity or
leaks and flooding during use should be considered.
1.3?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||