Standard Test Method for Corrosion of Surgical Instruments
STANDARD published on 1.9.2010
Designation standards: ASTM F1089-10
Note: WITHDRAWN
Publication date standards: 1.9.2010
SKU: NS-49092
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
boil test, copper sulfate corrosion test, corrosion-surgical implants, immersion, Boil test, Copper sulfate corrosion test, Corrosion--surgical implants, Immersion, Surgical instruments, ICS Number Code 11.040.30 (Surgical instruments and materials)
Significance and Use | ||||||
This test method provides a test methodology and means of evaluation consistent to both producers and users alike. The corrosion tests serve as an indicator of proper material processing selection by the manufacturers and proper care by the user. |
||||||
1. Scope | ||||||
1.1 This test method covers general test procedures and evaluation criteria for the corrosion resistance of surgical instruments intended for reuse in surgery and fabricated from stainless steel such as, but not limited to, those listed in Specification F899. 1.2 Austenitic (Class 3), martensitic (Class 4), precipitation hardenable (Class 5), and ferritic (Class 6) materials shall use the boil test. 1.3 Ferritic (Class 6) materials with a minimum 16 % chromium content, austenitic (Class 3), and precipitation hardenable (Class 5) materials shall use the boil test and the copper sulfate test. 1.4 The copper sulfate test is used to detect the presence of metallic iron and iron oxide on the surface of materials. 1.5 The copper sulfate test is not recommended for martensitic materials. (See Note X1.1.) 1.6 The boil test is applicable to martensitic, austenitic, ferritic, and precipitation hardenable materials to detect free iron or any other anodic surface contaminants on stainless steel. 1.7 Values in either inch-pound or SI are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore each system shall be used independent of the other. Combining values from the two systems may result in non-conformance with the specification. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historical
1.3.2013
Historical
1.6.2010
Historical
1.12.2011
Historical
1.6.2011
Historical
1.12.2007
Historical
1.3.2014
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.