We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Collection and Preparation of Blood for Dynamic in vitro Evaluation of Hemolysis in Blood Pumps
Translate name
STANDARD published on 1.9.2019
Designation standards: ASTM F1830-19
Publication date standards: 1.9.2019
SKU: NS-979024
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
blood trauma, condition of test blood, hemolysis, source of blood donor,, ICS Number Code 11.100 (Laboratory medicine)
Significance and Use | ||
5.1 In vitro hemolysis test results for blood pumps may be substantially affected by donor species, sex, age, fasting, the method of harvesting, the anticoagulant properties, the period of storage, the biochemical state of the blood, and the hemoglobin and hematocrit level of blood.3,4 Therefore, standardization of proper whole blood collection and preparation for the dynamic in vitro evaluation of blood pumps is essential, and this recommended practice will allow an acceptable comparison of test results among hemolysis tests involving similar testing methods. |
||
1. Scope | ||
1.1 This practice covers whole blood that will be used for the in vitro performance assessment of hemolysis in blood pumps intended for clinical use. 1.2 This practice covers the recommended standard collection, preparation, handling, storage, and utilization of whole blood for the in vitro evaluation (see Practice F1841) of the following devices: 1.2.1 Continuous flow blood pumps (roller pumps, centrifugal pumps, axial flow pumps, etc.). 1.2.2 Pulsatile and intermittent flow blood pumps (pneumatically driven, electro-mechanically driven, with an artificial pulse, etc.). 1.3 The source and preparation of whole blood utilized for the dynamic in vitro evaluation of red blood cell (erythrocyte) trauma caused by blood pumps can substantially influence the hemolysis performance of these devices. Thus, standardized whole blood collection and preparation methods are required. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||
2. Referenced Documents | ||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.