We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Determining Integrity of Seals for Flexible Packaging by Visual Inspection
STANDARD published on 1.8.2013
Designation standards: ASTM F1886/F1886M-09(2013)
Note: WITHDRAWN
Publication date standards: 1.8.2013
SKU: NS-51957
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
channels, minimum seal width, spotty seals, sterile package integrity, visual seal inspection, ICS Number Code 55.040 (Packaging materials and accessories)
Significance and Use | ||
5.1 Seal attributes can be linked directly to a number of variables in process parameters, equipment, or material, as well as environmental (room temperature and relative humidity). Visual seal characteristics and defects can provide evidence of package integrity and production sealing problems. 5.2 Visual seal defects often will be the first indication of heat sealing process variation. They also will indicate a lack of, or potential compromise to, package integrity after physical package performance testing. |
||
1. Scope | ||
1.1 This test method covers the determination of channels in the package seal down to a width of 75 μm [0.003 in.] with a 60–100 % probability (see Section 1.1.1 The ability to visually detect channel defects in package seals is highly dependent on the size of channel, the degree of contrast from sealed and unsealed areas, the amount and type of adhesive between the two package layers, reflecting light angle, types of material used, the use of magnification, and the inspector's level of training and experience. 1.2 This test method is applicable to packages with at least one transparent side so that the seal area may be clearly viewed. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Historical
1.3.2011
Historical
1.9.2011
Historical
1.11.2009
Historical
1.4.2013
Historical
15.4.2008
Historical
1.10.2013
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-29 (Number of items: 2 209 895)
© Copyright 2024 NORMSERVIS s.r.o.