We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Guide for Measurement of Ionizing Dose-Rate Survivability and Burnout of Semiconductor Devices
STANDARD published on 1.1.2011
Designation standards: ASTM F1893-11
Note: WITHDRAWN
Publication date standards: 1.1.2011
SKU: NS-51994
The number of pages: 7
Approximate weight : 21 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
burnout, failure, high dose-rate, integrated circuits, ionizing radiation, latchup, microcircuits, semiconductor devices, survivability, ICS Number Code 31.080.01 (Semi-conductor devices in general)
Significance and Use | ||||||||||
The use of FXR or LINAC radiation sources for the determination of high dose-rate burnout in semiconductor devices is addressed in this guide. The goal of this guide is to provide a systematic approach to testing semiconductor devices for burnout or survivability. The different types of failure modes that are possible are defined and discussed in this guide. Specifically, failure can be defined by a change in device parameters, or by a catastrophic failure of the device. This guide can be used to determine if a device survives (that is, continues to operate and function within the specified performance parameters) when irradiated to a predetermined dose-rate level; or, the guide can be used to determine the dose-rate burnout failure level (that is, the minimum dose rate at which burnout failure occurs). However, since this latter test is destructive, the minimum dose-rate burnout failure level must be determined statistically. |
||||||||||
1. Scope | ||||||||||
1.1 This guide defines the detailed requirements for testing semiconductor devices for short-pulse high dose-rate ionization-induced survivability and burnout failure. The test facility shall be capable of providing the necessary dose rates to perform the measurements. Typically, large flash X-ray (FXR) machines operated in the photon mode, or FXR e-beam facilities are utilized because of their high dose-rate capabilities. Electron Linear Accelerators (LINACs) may be used if the dose rate is sufficient. Two modes of test are described: (1) A survivability test, and (2) A burnout failure level test. 1.2 The values stated in International System of Units (SI) are to be regarded as standard. No other units of measurement are included in this standard. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.6.2014
Historical
1.12.2011
Historical
1.6.2009
Historical
1.10.2011
Historical
1.10.2011
Historical
1.7.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-09-01 (Number of items: 2 345 425)
© Copyright 2024 NORMSERVIS s.r.o.