Standard Test Method for Transformation Temperature of Nickel-Titanium Alloys by Thermal Analysis
STANDARD published on 1.6.2010
Designation standards: ASTM F2004-05(2010)
Note: WITHDRAWN
Publication date standards: 1.6.2010
SKU: NS-52407
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Nickel, chromium and their alloysTitanium and titanium alloys
Keywords:
differential scanning calorimeter, DSC, nickel-titanium alloy, NiTi, Nitinol, shape memory alloy, TiNi, transformation temperature, Nickel-titanium surgical implant alloys, Thermal analysis (TA)--metals/alloys, Transformation temperature, ICS Number Code 77.120.40 (Nickel, chromium and their alloys), 77.120.50 (Titanium and titanium alloys)
Significance and Use | ||||||||
Differential scanning calorimetry provides a rapid method for determining the transformation temperature(s) of nickel-titanium shape memory alloys. This test method uses small, stress-free, annealed samples to determine whether a sample of nickel-titanium alloy containing nominally 54.5 to 56.5 % nickel by weight is austenitic or martensitic at a particular temperature. Since chemical analysis of these alloys does not have sufficient precision to determine the transformation temperature by measuring the nickel to titanium ratio of the alloy, direct measurement of the transformation temperature of an annealed sample of known thermal history is recommended. This test method is useful for quality control, specification acceptance, and research. Transformation temperatures derived from differential scanning calorimetry (DSC) may not agree with those obtained by other test methods due to the effects of strain and load on the transformation. |
||||||||
1. Scope | ||||||||
1.1 This test method defines procedures for determining the transformation temperatures of nickel-titanium shape memory alloys. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historical
1.2.2013
Historical
1.5.2013
Historical
1.5.2013
Historical
1.1.2010
Historical
1.5.2012
Historical
1.4.2008
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-04 (Number of items: 2 210 925)
© Copyright 2024 NORMSERVIS s.r.o.