Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens
STANDARD published on 1.9.2010
Designation standards: ASTM F2147-01(2010)
Note: WITHDRAWN
Publication date standards: 1.9.2010
SKU: NS-52986
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
acute toxicity, allergenicity, biocompatibility, guinea pigs, immunotoxicity, sensitization, Cement mortars, ICS Number Code 11.100 (Laboratory medicine)
Significance and Use | ||||||
In selecting a material for human contact in medical applications, it is important to ensure the material will not stimulate the immune system to produce an allergic reaction under relevant exposure conditions. Extractable chemicals produced by skin contact or during physiological exposures may cause allergic reactions. Therefore, this practice provides for evaluations of solid or semisolid dosage forms using material extracts or direct evaluation of the test article. The rationale for this animal model is based on the fact that the guinea pig has been shown to be an appropriate animal model for predicting human contact dermatitis; its tractable nature, its availability from reputable suppliers, the historical database of information already acquired using this species, and the correlation of such results to data on known human allergens, all contribute to its widespread use for allergenicity studies (1-5). The need for sensitization procedures other than the maximization test (Practice F720) is based on: (1) the need for a route of exposure more similar to use conditions, (2) concern over the use of adjuvant because of its recruitment of cell types to the test site which are not typically involved in immunologic reactions, and because of the discomfort this causes in the animals, (3) absence of a proper FCA-irritant control group in the traditional maximization design, and (4) the frequency of false positives often encountered with the GPMT. Both of these tests are internationally accepted (1). |
||||||
1. Scope | ||||||
1.1 This practice is intended to determine the potential for a substance, or material extract, to elicit contact dermal allergenicity. 1.2 This practice is intended as an alternative to the Guinea Pig Maximization Test (GPMT), given the limitations on dosage form and tendency for false positives associated with the latter test. See Rationale and References. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historical
1.3.2013
Historical
1.3.2011
Historical
1.6.2013
Historical
1.6.2010
Historical
1.3.2010
Historical
1.12.2013
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.