We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Non-Destructive Detection of Leaks in Packaging Which Incorporates Porous Barrier Material by CO2 Tracer Gas Method
Translate name
STANDARD published on 15.1.2021
Designation standards: ASTM F2228-13(2021)
Publication date standards: 15.1.2021
SKU: NS-1018283
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Medical sciences and health care facilities in generalNon-destructive testing
Keywords:
basal flow, carbon dioxide (CO2) leak testing, flexible packaging, infrared CO2 sensor, medical packaging, non-destructive testing, package integrity monitoring, package integrity test, pass/fail criteria, pass/fail levels, permeable packaging, pinhole leaks, porous barrier, porous lids, porous packaging, rigid thermoformed trays, sealing membrane performance, seal integrity monitoring, seal integrity test, seal leaks, sterile integrity tests, trace gas leak testing,
Significance and Use | ||||||
5.1?Harmful biological or particulate contaminants may enter the package through incomplete seals or imperfections such as pinholes or cracks in the trays. 5.2?After initial instrument set-up and calibration, the operations of individual tests and test results do not need operator interpretation. The non-destructive nature of the test may be important when testing high value added products. 5.3?Leak test results that exceed the permissible threshold setting are indicated by audible or visual signal responses, or both, or by other means. 5.4?This non-destructive test method may be performed in either laboratory or production environments. This testing may be undertaken on either a 100 % or a statistical sampling basis. This test method, in single instrument use and current implementation, may not be fast enough to work on a production packaging line, but is well suited for statistical testing as well as package developmental design work. |
||||||
1. Scope | ||||||
1.1?This non-destructive test method detects leaks in non-porous rigid thermoformed trays, as well as the seal between the porous lid and the tray. The test method detects channel leaks in packages as small as 100 ?m (0.004 in.) diameter in the seal as well as 50 ?m (0.002 in.) diameter pinholes, or equivalently sized cracks in the tray, subject to trace gas concentration in the package, package design and manufacturing tolerances. Note 1:?This test method does not claim to challenge the
porous (breathable) lidding material. Any defects that may exist in
the porous portion of the package will not be detected by this test
method.
1.2?The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.3?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||
2. Referenced Documents | ||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.